23
IMPLEMENT SETTINGS
11.4
Valve settings
Set the type of valve installed on the system and the relevant values.
1
2
3
4
Fig. 43
5
6
Fig. 44
1
Main Valve > Type
Main control valve installed. Available options are:
None
,
2 ways
(drain valve),
3 ways
(main valve).
The items
Main Valve > Type
is shown as a REMINDER: it is activated during the guided setup (chap.
It can not therefore be modified on this screen.
2
Main Valve > Auto closing of section valves
Allows to enable/disable the section automatic closing when the main control valve is closed.
On a Seletron system, automatic closing of sections is enabled by default (
"M" type
).
•
"M" operation mode
(option
):
section valves are opened or closed by acting on the main control valve depending on the way the controls of the single section valves are set, i.e.:
-if the controls of the sections are set to OFF, and the main control is operated, the sections will remain closed;
-if the control of one or more section valves is ON, by closing or opening the main valve, also the section valves will be closed or opened.
ENABLED MODE CANNOT BE MODIFIED:
this condition occurs when no main valve is installed on the system or the installed one is a
2 ways
valve.
•
"P" operation mode
(option
):
the section valves are controlled independently.
Control functions on the main valve do not affect section valve opening or closing.
3
Main Valve > Auto closing of main valve
When all section valves are closed and this option is enabled, main valve automatic closing is performed as well.
(
Automatic closing of main valve enabled /
Automatic closing of main valve disabled).
4
Pressure regulating valve > Reverse direction
Indicate the type of installed control valve. Available options are:
Reverse direction enabled =
Reverse direction disabled =
5
Section valves > Type
Indicate the type of installed section valves. Available options are:
•
2 ways
(valves without calibrated backflows)
•
3 ways
(valves with calibrated backflows)
On a Seletron system, section valves are of the
2 ways
type (without calibrated backflows) and are automatically set.
6
Section valves > Nominal current
FOR SELETRON SYSTEMS, ONLY
Enter the maximum operating current value for each section valve.
Quits without confirming the
changes
Saves the changes
Delete
Quit
Confirm
Goes back to previous menu,
or scrolls the pages of a menu
(previous page)
Scrolls the pages of a menu
(next page)
Goes back to Main screen
Saves the changes to current
page