INSTALLATION, USE AND MAINTENANCE

4679004

4679005

IBX100 ECU CONTROL UNIT

Object Pool rel. 1.2.6

Summary of Contents for IBX100 4679004

Page 1: ...INSTALLATION USE AND MAINTENANCE 4679004 4679005 IBX100 ECU CONTROL UNIT Object Pool rel 1 2 6...

Page 2: ...nt in case of sale or change of ownership Keep it for future reference ARAG reserves the right to modify the specifications and instructions regarding the product at any time and without prior notice...

Page 3: ...ement geometry 29 11 11 System configurations 30 11 12 Fence 31 11 13 Flowmeter presets 31 12 Data and settings 32 12 1 Manage presets 32 12 2 Working parameters 34 12 3 Info and alarms 35 12 4 Implem...

Page 4: ...RAG components installed together with other brands components get damaged because of what stated above no direct or indirect warranty will be provided 1 RISKS AND PROTECTIONS BEFORE ASSEMBLY The job...

Page 5: ...es 1 Standard ISOBUS connector ISOBUS PLUG 2 Sensors control unit 3 Head end cable 4 Extension cable 5 Termination cable 6 Hydraulic ECU 7 Hydraulic unit 8 Auxiliary Input 9 Joystick Explorer S Speed...

Page 6: ...OLD MAX BOOM WIDTH 36 M 50 cm spacing 3 CENTRAL CABLES Code no of SELETRON nozzle holders Cable length m 467 491 C020 121 2 2 467 491 C020 120 2 9 5 467 491 C031 121 3 2 5 467 491 C031 120 3 10 467 49...

Page 7: ...unit 5 Auxiliary Input 6 Joystick Explorer S Speed sensor T Filling flowmeter X RPM sensor L Level sensor M Pressure sensor F Flowmeter P Control valve G Main valve INSTALLATION DIAGRAM SECTION VALVE...

Page 8: ...he cable length and make sure there is enough space for connectors and cables For any reference to the system configuration read par 5 1 Respect the mounting direction of the control units as specifie...

Page 9: ...MS ONLY NUM CONNECTION POINTS 1 Hydraulic unit 2 ECU IBX100 Sprayer NUM CONNECTION POINTS 1 Control unit G P Sensors 2 Control unit section valves SYSTEM WITH SECTION VALVES 3 Hydraulic unit 2 Seletro...

Page 10: ...may be damaged and compromise the system correct operation Use ONLY the cables and accessories indicated in the catalog having technical features suitable for the use to be made of them 6 2 Control un...

Page 11: ...n page 6 WARNING THE CABLES DESIGNED FOR CONNECTING TWIN SELETRON UNITS ON BOOMS UP TO 24 M LONG SHOULD NEVER BE USED ON LONGER BOOMS 2 ECU main control valve flowmeter and pressure sensor must be ins...

Page 12: ...code ECS0075 The plugs must be ordered separately When the connectors are plugged off the Seletron is sealed To avoid damaging the internal components make sure that when using or cleaning the system...

Page 13: ...Fix the connectors to the relevant valves according to the initials indicated in your assembly general diagram par 5 1 System recommended composition Remove the protection cap 1 Fig 21 from the electr...

Page 14: ...animals caused by failure to observe the above instructions ITEM CONNECTION F Flowmeter L Level sensor M Pressure sensor S Speed sensor T Filling flowmeter X RPM sensor The products are supplied with...

Page 15: ...ion connectors in Fig 25 make sure they are properly connected and turn the ring nut clockwise until blocking ARAG Auxiliary Input control system is not compulsory on all systems and must thus be orde...

Page 16: ...y may vary according to the VT being used In case of mismatch between the description herein and the information displayed on your VT refer to the manual supplied with it 8 1 OBJECT POOL loading Press...

Page 17: ...ailure to correctly connect system components or to use specified components might damage the device or its components 9 2 Command location MENU DATA SELECTION Fig 26 Goes back to main screen Goes bac...

Page 18: ...led on the control unit None 2 ways drain valve 3 ways main valve Spraying spot type Seletron type 1 single 2 twin 4 fourfold Flowrate reference sensor device used to calculate flowrate Flowmeter Pres...

Page 19: ...CAN BE FOUND IN Fig 34 This operation must be done once only when installing the computer ACCESS TO IMPLEMENT SETTINGS MENU 1 2 Fig 33 IMPLEMENT SETTINGS MENU STRUCTURE Fig 34 The gray items cannot b...

Page 20: ...as to fully exploit the number of permitted sections 5 Displays the type of installed end nozzles Basic settings chap 10 1 2 3 4 5 Fig 35 3a 3b Fig 36 Depending on the selected settings the total numb...

Page 21: ...lowrate pls l pls gal l min GPM l min GPM pls l pls gal l min GPM l min GPM 4621 x A0 xxxx 6000 22710 0 5 0 10 10 2 6 462 x 2 xxx 1025 3880 2 5 0 7 50 13 2 4621 x A1 xxxx 3000 11355 1 0 30 20 5 3 462...

Page 22: ...r the pressure sensor displays ONLY the job pressure Both the pressure sensor displays the job pressure when the machine works within the flowmeter limits When the flowmeter operates outside the limit...

Page 23: ...no main valve is installed on the system or the installed one is a 2 ways valve P operation mode option the section valves are controlled independently Control functions on the main valve do not affe...

Page 24: ...is calculated on the basis of the pulses received by the speed sensor installed on the wheel and directly connected to VT The wheel constant must be entered during the setup procedure 2 Tractor radar...

Page 25: ...when an alarm occurs please refer to par 16 3 5 Real time displaying of the actual datum 1 4 2 5 3 Fig 48 11 8 Tank Allows setting the tank values 1 Indicate range value The tank alarm is triggered wh...

Page 26: ...n the main valve and all section valves 1 Start the procedure by pressing Start 2 Press Confirmation to reset the pressure sensor residual signal 1 Fig 51 2 Value too low Value too high Unstable signa...

Page 27: ...dual signal 1 Fig 52 2 Value too low Value too high Unstable signal If this alarm is displayed faulty values have been detected check the conditions described at the beginning of the paragraph no resi...

Page 28: ...WITHIN THE FLOWMETER OPERATING RANGE 4 Start the procedure by pressing Start 5 Start the spraying system open in succession all section valves and the main control ON The display will show in real tim...

Page 29: ...l offset Fig 56 Fig 57 Fig 58 Boom lateral offset Application point Longitudinal axle 1 50 m NEGATIVE VALUES The application point is to the left of the longitudinal axle Fig 59 Application point Long...

Page 30: ...total counter control 7 AEnable disable section and main valve automatic closing 8 Enable disable the use of prescription maps for treatments with variable application TIMING The correct management o...

Page 31: ...imum flowrate and Maximum flowrate can be modified only when the option Other is enabled List of available flowmeters and preset data ORION FLOWMETERS WOLF FLOWMETERS Type Constant Minimum flowrate Ma...

Page 32: ...the Preset to be set 2 Type in the name 3 Enter the application rate value L Ha 4 Select the type of nozzle among the suggested ones 12 types of ISO nozzles and 6 customized nozzles Nozzle type thanks...

Page 33: ...e the job data WARNING total counters and average values are simultaneously deleted 1 1 2 Fig 69 Quits without confirming the changes Saves the changes Delete Quit Confirm Goes back to previous menu o...

Page 34: ...may indicate wrong measurements to correct this measurement edit the sprayed liquid weight referred to 1 liter of product A tank level sensor must be installed 5 Enable item Regulating valve positioni...

Page 35: ...ld in point 6 6 Set the acceptable threshold the VT compares the effective rate read by the flowmeter and the one calculated by the pressure sensor When the difference between the two rate values exce...

Page 36: ...nt settings Advanced setup 12 5 Job data Allows user to view total spraying data concerning sprayed area and work time Fig 75 12 6 Sprayer capability Allows checking treatment performance based on spe...

Page 37: ...12 7 4 par 12 7 5 par 12 7 6 Fig 77 12 7 1 Device status Displays system information Hardware working correctly Hardware malfunction Fig 78 Quits without confirming the changes Saves the changes Dele...

Page 38: ...k to Main screen Saves the changes to current page 12 7 2 ISOBUS 1 2 3 Fig 79 Displays information on ISOBUS protocol 1 Allows displaying the OP on another VT if any present on the ISOBUS line 2 Allow...

Page 39: ...ready been completed and screen is displayed without any waiting time Key used to display ISOBUS sprayer management application 2 Enables disables simulation mode mainly used for demonstrative purpose...

Page 40: ...rocedure chap 13 Seletron connection DIAGNOSTICS Allows to check the connection of each single Seletron CARRY OUT both procedures with RUNNING ENGINE SELETRON CONNECTION DIAGNOSTICS Color legend Corre...

Page 41: ...s any kind of setting The operator only carries out the treatment Manager the use at this level inhibits machine feature setting but allows treatment configuration You can set an access PIN code Techn...

Page 42: ...ATTHE PROCEDURE FROMTHE START ID Reset PAR 13 1 Connect the first Seletron Seletron no 1 is the first on the left when looking at the boom from behind Fig 86 WAIT FOR THE ACOUSTIC SIGNAL BY THE MONITO...

Page 43: ...NCE FOR FOURFOLD SELETRON DEVICES CONNECTOR 1 CONNECTOR 2 NOZZLE A NOZZLE C NOZZLE B NOZZLE D 1 2 Fig 89 1 Connect in sequence ONLY SELETRON NOZZLE HOLDERS A AND B from left to right until the end of...

Page 44: ...ndicated settings Main control ON Open sections Enabled nozzles MANUAL nozzle selection settings MANUAL section management settings HOME SCREEN MANUAL nozzle selection settings Enabled nozzles Par 11...

Page 45: ...t possible to proceed with the installation of the following Seletron Tighten each Seletron onto the relevant nozzle holder using a torque wrench and a tightening torque of 4 5 Nm 40 Inch lbs Alternat...

Page 46: ...Task Controller function status par 11 11 ON OFF variable application ON OFF section automatic management Check of ON OFF job counters Tank level text and graphic alternated with range on surface ON...

Page 47: ...screen press This screen summarizes the alarm notifications active for the operators or the just solved alarms Fig 96 For the procedure to be followed when an alarm occurs please refer to par 16 3 HO...

Page 48: ...s the changes Delete Quit Confirm Goes back to previous menu or scrolls the pages of a menu previous page Scrolls the pages of a menu next page Goes back to Main screen Saves the changes to current pa...

Page 49: ...lection is enabled the VT using Seletron devices will enable the nozzle or combination of nozzles according to the set spray rate and driving speed This system allows to widen the machine operating ra...

Page 50: ...ing flowmeter The computer calculates the quantity of fluid inside the tank by processing the job data and allows to enable several manual procedures Level reset Filled quantity manual setup Tank leve...

Page 51: ...than tank total capacity TANK FILLING 1 2 Fig 111 1 2 Press to set tank level to the maximum value The display will show the tank as full its total capacity has been set during advanced setup par 11 8...

Page 52: ...y through the monitor touch screen panel keys B To display the necessary controls on the touch screen panel the desired auxiliary control must nevertheless be set par 11 11 MAIN CONTROL FROM TOUCH SCR...

Page 53: ...s to the right starting from the first available on the left Press to close the sections to the left starting from the first available on the right x 2 x 1 x 2 x 1 HYDRAULIC CONTROLS FROM TOUCH SCREEN...

Page 54: ...PANEL Activation of the left hand special nozzle when looking at the boom from behind Press switch once to the left to activate the left hand nozzle for Buffer zone and close the standard nozzle The L...

Page 55: ...the VT Following are some examples END NOZZLES CORRESPONDING ICON ON HOME SCREEN Special nozzle LEFT ENABLED Special nozzle RIGHT ENABLED Special nozzle LEFT DISABLED Special nozzle RIGHT DISABLED EXA...

Page 56: ...ith Virtual Terminal and loading of Object Pool 3 periodical blinks ERROR OP loading on VT failed 4 periodical blinks SEVERE ERROR internal flash drive formatting in progress consistent blinks control...

Page 57: ...ter ON Flowmeter out of max value Flowmeter out of min value Flowrate out of range Max Flowrate out of range Min Rate out of the limits allowed by flowmeter Modify working conditions to suit flowmeter...

Page 58: ...ot match litres gpm actually sprayed Wrong setup Check the setup of the flowmeter constant Check the setup of the section valve type Distance travelled count not reset Reset counter Three way section...

Page 59: ...or to alterations resulting from environmental climatic or other conditions damage due to the use of unsuitable chemical products for spraying watering weedkilling or any other crop treatment that may...

Page 60: ...ALY Via Palladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 http www aragnet com info aragnet com Only use original ARAG accessories and spare parts to maintain safety conditions foreseen by the constr...