43
7.4
Checking the hydraulic hoses
Have the hydraulic hoses checked annually by a qualified technician. The inspection
intervals to be observed may be regulated by regional laws and regulations.
According to DIN 20066, all hydraulic hoses must be replaced after 6 years at the lat-
est.
7.5
Repairs and service
In case of failure or damage to the seed drill, please contact the manufacturer. You
can find information for this under
Contact Service
On page 5.
In this section, you will learn how to decommission the seed drill, store it for longer
periods of time, and dispose of it.
8.1
Decommissioning the seed drill
Purpose
To ensure that the seed drill remains fully functional even if it is out of operation for
longer periods of time, it is important to take precautions for storage.
Procedure
This is how to prepare the seed drill for storage:
Step
Description
1
Completely remove all seed from the seed drill.
2
Clean the seed drill inside and out, see
Cleaning the seed drill
On page
42 for more information.
3
Set the brush adjustment lever to Position "+4".
4
Store the seed drill in a dry place to prevent the formation of germs inside
the implement.
8.2
Storage of the seed drill
The seed drill must be stored in a dry place protected from weather conditions to en-
sure that it remains functional even if it is stored for a longer period of time.
8.3
Disposal
Disposal of the seed drill must be performed according to the local disposal regula-
tions for machines.
8
Decommissioning, storage and disposal
Summary of Contents for HG 300 M1