25
prevent damage to the seeding shaft. In addition, a flex seeding shaft must be used
for coarse seed types to prevent damage to the seeding shaft or the seed.
Requirements
The following requirements must be fulfilled for this work step:
•
The implement is disconnected from the power source, see
Disconnecting the
seed drill from the power source
On page 40.
Required components, tools and materials
For this work step, the following components, tools and materials are required:
Hexagon key
Torx screwdriver TX 30
Procedure
This is how you remove the swell air plate:
Step
Description
Explanation
1
Loosen the hexagonal bolt (2) on the
calibration slide (1).
2
Remove the calibration slide.
3
Loosen the Torx screws (3) and remove
the swell air plate (4).
4.6
Connecting the hydraulic fan (HF)
Purpose
The hydraulic fan is used for operation with working widths up to 12 m or for higher
spread rates of e.g. wheat.
Summary of Contents for HG 300 M1