28
Procedure
This is how to set the hydraulic fan:
Version 1
(Constant pump – non-adjustable oil quantity on the tractor)
Step
Description
1
Completely close the flow control valve (2) on the hydraulic block (1).
2
Start up the blower fan (tractor engine speed as in field operation).
3
Adjust the fan speed using the flow control valve (2) on the control block.
Version 2
(Variable pump - oil quantity adjustable on the tractor):
Step
Description
1
Completely open the flow control valve (2) on the hydraulic block (1).
2
Completely close the flow control valve on the tractor (set the oil quantity to
zero).
3
Start up the fan and run up to the desired fan speed (slowly increase the oil
quantity).
Setting table for the flow control valve
(valid for approx. 50°C oil temperature)
Working width 3 m
Seed
Rate
Pressure
Speed
Fine seed
5 kg/ha
5 bar
1400 rpm
Fine seed
30 kg/ha
15 bar
2900 rpm
Coarse seed
50 kg/ha
18 bar
3000 rpm
Coarse seed
100 kg/ha
19 bar
3100 rpm
Working width 6 m
Fine seed
5 kg/ha
8 bar
1550 rpm
Fine seed
30 kg/ha
20 bar
3300 rpm
Coarse seed
50 kg/ha
21 bar
3400 rpm
Coarse seed
100 kg/ha
22 bar
3500 rpm
Working width 12 m
Fine seed
5 kg/ha
10 bar
1650 rpm
Fine seed
30 kg/ha
35 bar
4000 rpm
Coarse seed
50 kg/ha
39 bar
4200 rpm
Coarse seed
100 kg/ha
41 bar
4300 rpm
Summary of Contents for HG 300 M1