26
Requirements
The following requirement must be fulfilled for this work step:
•
The hydraulic system is depressurized both on the tractor and implement side.
Required components, tools and materials
For this work step, the following components, tools and materials are required:
•
Coupling connector or coupling sleeve (for initial operation)
Overview
No. Designation
1
Hydraulic block
2
Flow control valve
3
Coupling sleeve (alternative)
4
Coupling connector
5
Return line
6
Pressure line
Procedure
This is how to connect the hydraulic fan:
Step
Description
1
Completely close the flow control valve (2) on the hydraulic block (1).
2
Connect the return line (5) (marked in yellow, BG4) without reduction to the
return flow connection of the tractor hydraulic system.
For initial operation: Remove the plastic plug on the return line and connect
the coupling plug (4) or the coupling sleeve (3) with the return line.
3
Connect the pressure line (6) (marked in red, BG3) with a pressure con-
nection of the tractor hydraulic system.