6
DS43364-001
1
IMPORTANT SAFETY INSTRUCTIONS
ATTENTION - FOR REASONS OF PERSONAL SAFETY IT IS IMPORTANT TO OBSERVE THESE
INSTRUCTIONS.
RETAIN THESE INSTRUCTIONS
Do not let children play with fixed control devices.
Keep the remote controls out of reach of children.
Perform frequent checks on the system for any signs of unbalance and wear or damage to wires
or springs.
Do not use the equipment if it requires repair or regulation.
These warning symbols serve to remind you to pay the maximum attention when the equipment
is in use.They indicate the procedures to be followed to avoid risks to persons or things.This
gearmotor is designed to function safely if installed and used in compliance with the following
instructions. The equipment must be employed for residential uses and must be installed
indoors.
You are warned that incorrect installation can cause serious injuries.
Follow all the installation instructions.
Do not use command buttons that can simultaneously operate the equipment in both directions.
Do not command more than one gearmotor with each button.
Conduct frequent examinations on the installation to check for signs of unbalance and
wear/damage to the wiring.
Do not use the equipment if it requires repairs or adjustments.
The product cannot be installed for heights of less than 2.5. m.
The deployment of a device that guarantees omnipolar disconnection from the mains with an
opening of at least 3 mm between the contacts is obligatory.
Before installing the gearmotor for operating the rolling shutter remove all superfluous wires and
disable any equipment not necessary for motorised movement.
The control button must be placed in sight of the equipment, kept separate from the moving parts
and at a height of at least 1.5 m.
If the power cables are damaged they must be replaced by the constructor or his technical after-
sales service or, in any case, by a similarly qualified person in order to avoid all risks.
The gearmotor is designed for intermittent operation and is provided with an internal thermal
protection that interrupts power supply in the event of overheating caused by continued use.
The gearmotor automatically resets itself after a few minutes. However, regular operation will
only be possible when the gearmotor cools down.
2
TECHNICAL CHARACTERISTICS
Model
Torque
Nm
R.P.M
Capacitor
µF
Voltage
Volt
Current
A
Power
W
Thermal
min
Weight
Kg
Ro-Matic RS140 -
43364/001
140
10
18
230
2.5
520
4min
8
Ro-Matic RS140
EB - 43364/002
130
10
18
230
2.5
520
4min
9
Ro-Matic RS180 -
43364/003
180
10
22
230
3.1
700
4min
10
Ro-Matic RS180
EB - 43364/004
170
10
22
230
3.1
700
4min
11