FST 500 Manual
- Page 32 -
Chapter 4 Parameters
This FST-500 AC motor drive has 157 parameters for easy setting. In most applications, the user can
finish all parameter settings before start-up without the need for re-adjustment during operation.
4.1 Summary of Parameter Settings
※
The parameter can be set during operation.
Parameter
Explanation
Settings
Factory
Setting
※
Pr.00
Source of Frequency
Command
00: Master frequency determined by digital
keypad (LC-M02E)
01: Master frequency determined by 0 to
+10 V input on AVI terminal with jumpers
02: Master frequency determined by 4 to
20mA input on ACI terminal with jumpers
03: Master frequency determined by RS-485
Communication port
04: Master frequency determined by
potentiometer on digital keypad
00
※
Pr.01
Source of Operation
command
00: Operation determined by digital keypad
01: Operation determined by external control
terminals, keypad STOP is effective
02: Operation determined by external control
terminals, keypad STOP is ineffective
03: Operation determined by RS-485
communication port, keypad STOP is effective
04: Operation determined by RS-485
communication port, keypad STOP is
ineffective
00
Pr.02
Stop Method
00: Ramp stop
01: Coast Stop
00
Pr.03
Maximum Output
Frequency
50.00 to 400.0 Hz
60.00
Pr.04
Maximum Voltage
Frequency (Base
Frequency)
10.00 to 400.0Hz
60.00
Pr.05
Maximum
Output
Voltage (Vmax)
115V/230V: 0.1 to 255.0V
220.0
460V: 0.1 to 510.0V
440.0
575V: 0.1 to 637.0V
575.0
Pr.06
Mid-point Frequency
0.10 to 400.0Hz
1.50
Pr.07
Mid-point Voltage
115V/230V: 0.1 to 255.0V
10.0
460V: 0.1 to 510.0V
20.0
575V: 0.1 to 637.0V
26.1
Summary of Contents for FST-500 Series
Page 8: ...FST 500 Manual Page 8 1 1 3 External Parts and Labels...
Page 9: ...FST 500 Manual Page 9 1 1 4 Remove instructions...
Page 17: ...FST 500 Manual Page 17...
Page 22: ...FST 500 Manual Page 22 2 4 Control Terminal Wiring Factory Settings...
Page 27: ...FST 500 Manual Page 27 3 1 2 How to Operate the Digital Keypad LC M02E...
Page 49: ...FST 500 Manual Page 49 Commonly used V F Setting 1 General Purpose...
Page 110: ...FST 500 Manual Page 110 Chapter 5 Troubleshooting 5 1 Over Current OC...
Page 111: ...FST 500 Manual Page 111 5 2 Ground Fault 5 3 Over Voltage OV...
Page 112: ...FST 500 Manual Page 112 5 4 Low Voltage Lv...
Page 113: ...FST 500 Manual Page 113 5 5 Over Heat OH1 5 6 Overload...
Page 114: ...FST 500 Manual Page 114 5 7 Keypad Display is Abnormal 5 8 Phase Loss PHL...
Page 115: ...FST 500 Manual Page 115 5 9 Motor cannot Run...
Page 116: ...FST 500 Manual Page 116 5 10 Motor Speed cannot be Changed...
Page 134: ...FST 500 Manual Page 134...
Page 135: ...FST 500 Manual Page 135...
Page 145: ...FST 500 Manual Page 145 EMI Filter 40TDS4W4B Used on 5 7 5 HP 230V Three Phase Models...