B.5 Zero Phase Reactor (RF220X00A)
Dimensions are in millimeter
Cable
type
(Note
Recommended Wire
Size
Qt
y.
Wiring
Method
AWG
mm
2
Nominal
(mm
2
)
Single-
core
≦
10
≦
5.3
≦
5.5
1
Diagram
A
≦
2
≦
33.6
≦
38
4
Diagram
B
Three-
core
≦
12
≦
3.3
≦
3.5
1
Diagram
A
≦
1
≦
42.4
≦
50
4
Diagram
B
Note:
600V Insulated Unshielded Cable
Diagram A
Please wind each wire
4 times
around the core.
The reactor must be put at inverter side
Diagram B
Please put all wires through 4 cores in
series without winding.
Note 1: The table above gives approximate wire
size for the zero phase reactors but the selection
is ultimately governed by the type and diameter of
cable fitted i.e. the cable must fit through the
center hole of zero phase reactors.
Note 2: Only the phase conductors should pass
through, not the earth core or screen.
Note 3: When long motor output cables are used,
an output zero phase reactor may be required to
reduce radiated emissions from the cable.
Summary of Contents for FST-500 Series
Page 8: ...FST 500 Manual Page 8 1 1 3 External Parts and Labels...
Page 9: ...FST 500 Manual Page 9 1 1 4 Remove instructions...
Page 17: ...FST 500 Manual Page 17...
Page 22: ...FST 500 Manual Page 22 2 4 Control Terminal Wiring Factory Settings...
Page 27: ...FST 500 Manual Page 27 3 1 2 How to Operate the Digital Keypad LC M02E...
Page 49: ...FST 500 Manual Page 49 Commonly used V F Setting 1 General Purpose...
Page 110: ...FST 500 Manual Page 110 Chapter 5 Troubleshooting 5 1 Over Current OC...
Page 111: ...FST 500 Manual Page 111 5 2 Ground Fault 5 3 Over Voltage OV...
Page 112: ...FST 500 Manual Page 112 5 4 Low Voltage Lv...
Page 113: ...FST 500 Manual Page 113 5 5 Over Heat OH1 5 6 Overload...
Page 114: ...FST 500 Manual Page 114 5 7 Keypad Display is Abnormal 5 8 Phase Loss PHL...
Page 115: ...FST 500 Manual Page 115 5 9 Motor cannot Run...
Page 116: ...FST 500 Manual Page 116 5 10 Motor Speed cannot be Changed...
Page 134: ...FST 500 Manual Page 134...
Page 135: ...FST 500 Manual Page 135...
Page 145: ...FST 500 Manual Page 145 EMI Filter 40TDS4W4B Used on 5 7 5 HP 230V Three Phase Models...