Panel Layout

 Remote lamp

Lights up when the MS2830A is in a remote control state.

 Preset key

Resets parameters to their initial settings.

 Function keys

Used for selecting or executing function menu displayed 

on the right of the screen. The function menu contents 

are provided in multiple pages and layers.

 Application key

Press to switch between applications.

 Shift key

Used to operate any keys with functions described in 

blue characters on the panel. First press the Shift key, 

then press the target key when the Shift key lamp lights 

up green.

 Main function keys 2

Used to set or execute main functions of the MS2830A.

Executable functions vary depending on the application 

currently selected.

 Rotary knob/Cursor keys/Enter key/Cancel key

The rotary knob and cursor keys are used to select 

display items or change settings.

 Main function keys 1

Used to set or execute main functions of the MS2830A.

Executable functions vary depending on the application 

currently selected.

 RF Input connector

Inputs an RF signal.

 Numeric keypad

Used to enter numbers on parameter setup screens.

 USB connector (type A)

Used to connect a USB keyboard or mouse or the USB 

memory supplied with the MS2830A.

 Power switch

Press to switch between the standby state in which AC 

power is supplied and the Power On state in which the 

MS2830A is under operation. The Power lamp 

lights up orange in the standby state, and lights up green 

in the Power On state. Press the power switch for a 

reasonably long duration (for about two seconds).

 SG Output connector

Outputs an RF signal, when the vector signal generator 

option is installed.

 HDD lamp

Lights up when the MS2830A internal hard disk is being 

accessed.

 Mod On/Off key

When the vector signal generator option is installed, RF 

signal modulation can be turned on and off by pressing     .

When modulation is on, the key lamp lights up green.

 SG On/Off key

If the Vector Signal Generator option is installed, 

pressing     enables (On) or disables (Off) the RF signal 

output. The lamp of the RF output control key lights up 

orange when the RF signal output is set to On.

 Copy key

Press to capture a screen image from the display and 

save it to a file.

 Recall key

Press to recall a parameter file.

 Save key

Press to save a parameter file.

 Cal key

Press to display the calibration execution menu.

 Local key

Press to return to local operation from remote control 

operation through GPIB, Ethernet or USB (B), and 

enable panel settings.

4  

Product Brochure

 

l

 

MS2830A

Summary of Contents for MS2830A-040

Page 1: ...Signal Analyzer MS2830A 040 9 kHz to 3 6 GHz MS2830A 041 9 kHz to 6 GHz MS2830A 043 9 kHz to 13 5 GHz MS2830A 044 9 kHz to 26 5 GHz MS2830A 045 9 kHz to 43 GHz See catalog for MS2830A 044 045 Product...

Page 2: ...and linearity error Since it gives an instinctive impression of measurement instrument error it lowers the risk of measurement errors Frequency 500 MHz 2 GHz 0 5 dB Frequency 5 GHz 12 GHz 1 8 dB Freq...

Page 3: ...NC346 series 9 Requires Opt 006 10 Requires Opt 005 and Opt 006 11 Requires Opt 005 Opt 006 and Opt 077 Signal Analyzer Functions Opt 005 006 077 078 Analysis Bandwidth Opt 006 10 MHz max 20 MHz max...

Page 4: ...rd or mouse or the USB memory supplied with the MS2830A Power switch Press to switch between the standby state in which AC power is supplied and the Power On state in which the MS2830A is under operat...

Page 5: ...nal reference frequency signal 5 10 13 MHz It is used for inputting reference frequency signals with accuracy higher than that of those inside the MS2830A or for synchronizing the frequency of the MS2...

Page 6: ...frequency point which causes errors when the frequency changes The MS2830A has a built in calibration oscillator for level calibration over a wide frequency range from 300 kHz to 4 GHz minimizing mea...

Page 7: ...ifications if measurement requires addition of a margin to the product test specification Since specifications with added margin are severe even genuinely passing products may sometimes be evaluated a...

Page 8: ...o measure The MS2830A has an excellent dynamic range supporting true performance measurements of devices such as base stations requiring wideband measuring instruments Distortion Characteristics Spect...

Page 9: ...than that of conventional spectrum analyzers but sometimes a power meter is used when wanting to measure with even higher accuracy However use of a power meter narrows the dynamic range and errors ma...

Page 10: ...ger Function Trigger sweep executes sweeping using the specified trigger condition as the start point In particular SG Marker starts analyzer measurement in synchrony with the signal output by install...

Page 11: ...An image response is received when setting the bandwidth to more than 31 25 MHz This can be used when not inputting a signal frequency outside the MS2830A analysis bandwidth 125 MHz max The MS2690A 9...

Page 12: ...Hz 200 s 100M 500 kHz 1 MHz 100 s 100M 1 MHz 2 MHz 50 s 100M 2 5 MHz 5 MHz 20 s 100M 5 MHz 10 MHz 10 s 100M 10 MHz 20 MHz 5 s 100M 25 MHz 50 MHz 2 s 100M 31 25 MHz 50 MHz 2 s 100M 50 MHz 100 MHz 500 m...

Page 13: ...1 APD 2 The CCDF trace displays the power variation probability on the y axis and power variation on the y axis to confirm the CCDF and APD of measured signals 1 CCDF Complementary Cumulative Distribu...

Page 14: ...b trace supports easy monitoring of fault locations and transient phenomena Main Spectrum Frequency vs Time Power vs Time Phase vs Time CCDF APD Spectrogram Sub Power vs Time Spectrogram The part of a...

Page 15: ...e Sub trace Display Confirm analysis range in sub trace and target signal status on main trace Analysis range Analysis range Analysis range Analysis range Signal Analyzer Trace Product Brochure l MS28...

Page 16: ...to the internal hard disk and can be output to an external PC via a high speed interface such as the 1000BASE T LAN port Captured Waveform Output from Vector Signal Generator Option Waveforms captured...

Page 17: ...band Total power in channel band Measurement Results Absolute power of Offset channel Relative values in relation to reference power selected in ACP reference Channel Power This function measures chan...

Page 18: ...p positions on the screen True performance is measured using the noise cancellation function to subtract main frame noise from the measurement result Pre installed templates for each standard support...

Page 19: ...ers be listed below the trace but the differences between markers can be calculated and displayed using the delta setting SPA VSA Highest 10 Markers This function sets the threshold level and auto det...

Page 20: ...GHz 100 kHz 40 to 20 dBm MA24104A has been discontinued Measurement Results Marker point frequency Frequency Counter This function of the marker functions is used to measure CW frequencies Gate Time...

Page 21: ...he specifications Noise Figure Measurement Opt 017 Measurement Result Example of Graph display Frequency Mode Sweep Screen Layout Graph Measurement Result Example of List display Frequency Mode List S...

Page 22: ...5 M 0 01 to 18 0 14 to 16 1 15 1 1 25 1 No Not required NC346B Option 1 N M 0 01 to 18 0 14 to 16 1 15 1 1 35 1 No Not required NC346B Option 2 APC7 0 01 to 18 0 14 to 16 1 15 1 1 25 1 No Not required...

Page 23: ...Hz Opt 021 Resolution 0 01 Hz step The Vector Signal Generator option Opt 020 021 frequency range is 250 kHz to 3 6 GHz 6 0 GHz covering the key wireless communication range Output Level Range Output...

Page 24: ...A 020 021 arbitrary waveform memory can save MAX 256 Msamples channel as well as multiple waveform patterns at the same time Waveform patterns in memory can be output instantaneously by switching with...

Page 25: ...ch communication method Simulation Function for checking generated waveform pattern before transfer to CCDF and FFT graphs Conversion Function for converting ASCII format waveform patterns created by...

Page 26: ...ix PN15Fix PN20Fix PN23Fix UserDefine 4096 bits Max Measurable Bit Count 1000 to 4294967295 bits 232 1 bits Measurable Error Bit Count 1 to 2147483647 bits 231 1 bits Count Mode Data Measures until sp...

Page 27: ...mance is increasingly important at carrier offsets of 1 kHz to 100 kHz Spectrum analyzer phase noise performance affects ACLR MASK measurements at narrowband communications Channel bandwidth 100 kHz A...

Page 28: ...memory capacity from 64 Msample to 256 Msample MS2830A 028 128 AWGN Retrofit AWGN generator function MS2830A 313 Removable HDD The MS2830A 313 Removable HDD is useful when a user takes the instrument...

Page 29: ...alysis Bandwidth Extension Option Configuration Maximum Analysis Bandwidth In band carrier aggregation range Maximum Number of Bands Maximum Number of Component Carriers MS269xA Opt 078 installed 125...

Page 30: ...802 11a b g Bluetooth Option Patterns MX269970A 1xEV DO Reverse Receiver Test Waveform Pattern Measurement Software for Smart Meter This software is for PC This software supports automatic measurement...

Page 31: ...1 002 Aging rate 1 10 6 year 1 10 7 day Temperature stability 2 5 10 6 5 to 45 C with MS2830A 001 23 C Referenced to frequency at 24 hour after power on Start up characteristics 1 10 9 7 minutes after...

Page 32: ...mode Normal 300 kHz f 3 5 GHz Frequency band mode Spurious 1 8 dB 4 GHz f 6 GHz Frequency band mode Normal 3 5 GHz f 6 GHz Frequency band mode Spurious 1 dB gain compression without MS2830A 008 or Pr...

Page 33: ...nterface function SH1 AH1 T6 L4 SR1 RL1 PP0 DC1 DT0 C0 E2 USB B USB B connector USB2 0 Rear panel USB USB A connector USB2 0 Front panel 2 ports Rear panel 2 ports Monitor output Mini D Sub 15 pin Com...

Page 34: ...f 6 GHz MS2830A 041 043 142 dBm Hz 6 GHz f 13 5 GHz MS2830A 043 with MS2830A 008 Preamp On 147 dBm Hz 100 kHz nominal 156 dBm Hz 1 MHz 163 dBm Hz 30 MHz f 1 GHz 162 dBm Hz 1 GHz f 2 GHz 160 dBm Hz 2 G...

Page 35: ...00 MHz 101 201 251 401 501 1001 2001 5001 10001 100 MHz Span 500 MHz 300 Hz Span 100 MHz Sweep time 10 s 11 21 41 51 101 201 251 401 501 1001 2001 5001 10001 300 Hz Span 100 MHz Sweep time 10 s Span 0...

Page 36: ...5 sequence with MS2830A 077 2 kHz to 200 MHz 1 2 5 sequence with MS2830A 078 Capture time without MS2830A 077 078 or 31 25 MHz bandwidth Setting capture time length Minimum capture time length 2 s to...

Page 37: ...0 dB Mixer input level 10 dBm 0 5 dB 300 kHz f 4 GHz Frequency band mode Normal 300 kHz f 3 5 GHz Frequency band mode Spurious 1 8 dB 4 GHz f 6 GHz Frequency band mode Normal 3 5 GHz f 6 GHz Frequency...

Page 38: ...layed function Function outline Displayed phase time fluctuation of input signal from captured waveform data Analysis time range Analysis start time Sets analysis start time point from waveform data h...

Page 39: ...730000 14 6 ms 50 MHz 100 MHz 730000 7 3 ms 62 5 MHz 100 MHz 730000 7 3 ms 100 MHz 200 MHz 730000 3 65 ms 125 MHz 200 MHz 730000 3 65 ms MS2830A 017 Noise Figure Measurement Function Frequency Frequen...

Page 40: ...thout MS2830A 022 Output level p dBm 0 5 dB typ 25 MHz 40 p 2 0 5 dB typ 25 MHz f 375 MHz 40 p 9 0 5 dB 375 MHz f 3 6 GHz 40 p 9 0 8 dB 3 6 GHz 40 p 4 with MS2830A 022 Output level p dBm 1 0 dB typ 25...

Page 41: ...n signal input Aux connector Rear panel TTL H Signal On L Signal Off Arbitrary waveform generator Waveform resolution 14 15 16 bits Marker output 14 bits Three signals in waveform pattern or real time...

Page 42: ...iable error free Select header bit used at sync detection Re synchronization Judgment Condition x y Resynchronization at detection of x bit error in y bits y Measured bit count Select from 500 bits 50...

Page 43: ...m Hz 30 MHz f 1 GHz 161 dBm Hz 1 GHz f 2 GHz 158 dBm Hz 2 GHz f 3 5 GHz 154 dBm Hz 3 5 GHz f 4 GHz Frequency band mode Normal MS2830A 041 043 154 dBm Hz 3 5 GHz f 4 GHz Frequency band mode Spurious MS...

Page 44: ...to 100 MHz 1 2 5 sequence with MS2830A 077 2 kHz to 200 MHz 1 2 5 sequence with MS2830A 078 Capture time with MS2830A 077 31 25 MHz bandwidth Setting capture time length Minimum capture time length 1...

Page 45: ...dBm Hz 6 GHz f 13 5 GHz MS2830A 043 with MS2830A 066 MS2830A 008 Preamp On 153 5 dBm Hz 300 MHz f 1 GHz 152 5 dBm Hz 1 GHz f 2 GHz 149 5 dBm Hz 2 GHz f 3 5 GHz 145 5 dBm Hz 3 5 GHz f 6 GHz MS2830A 041...

Page 46: ...No No No No 026 BER Measurement Function 027 ARB Memory Upgrade 256 MSa for Vector Signal Generator No No No R No No 3 3 028 AWGN No No No R No No 3 3 029 Analog Function Extension for Vector Signal G...

Page 47: ...ment Software R R 1 MX269022A 001 LTE Advanced TDD Downlink Measurement Software R R 1 U U Require MX269022A MX269023A LTE TDD Uplink Measurement Software R R 1 MX269024A CDMA2000 Forward Link Measure...

Page 48: ...MX269026A MX269026A 001 MX269028A MX269028A 001 MX269030A MX283027A MX283027A 001 MX283027A 002 MX283087A Software options CD ROM with License and Operation manuals Mobile WiMAX Measurement Software...

Page 49: ...Manual Remote Control MX283027A 002 Operation Manual Operation MX283027A 002 Operation Manual Remote Control W3448AE W3449AE MX283087A Operation Manual Operation MX283087A Operation Manual Remote Cont...

Page 50: ...A AUX Conversion Adapter B0671A Front Cover for 1MW4U MS2830A with Front Cover MA24106A USB Power Sensor B0636C Carrying Case Hard type with casters B0645A Soft Carrying Case 50 Product Brochure l MS2...

Page 51: ...Note Product Brochure l MS2830A 51...

Page 52: ...G WK IORRU 5XVVLD 0RVFRZ 3KRQH D x 8QLWHG UDE PLUDWHV QULWVX 0 WG XEDL LDLVRQ 2IILFH 3 2 R XEDL QWHUQHW LW O 7KXUD D XLOGLQJ 7RZHU 6XLW WK ORRU XEDL 8QLWHG UDE PLUDWHV 3KRQH D x QGLD QULWVX QGLD 3ULYD...

Reviews: