Unified Fieldbus Controller UFC100-L2 – Basic mode operation
Page 26
Rev. 1.0
Proprietary and confidential information of Aniotek Inc.
21 May 2018
4 E
LECTRICAL AND
T
EMPERATURE
S
PECIFICATIONS
4.1
Absolute Maximum Ratings
Symbol
Parameter
Min
Max
Units
VDD
Supply Voltage
– 0.3
4.0
V
VI
DC Input Voltage
– 0.3
VDD + 0.3
V
VO
DC Output Voltage
– 0.3
VDD + 0.3
V
TJ
Junction Temperature
– 40
125
0
C
4.2
Operating Conditions
Symbol
Parameter and condition
Min
Typical
Max
Units
Note
VDD
Supply voltage
2.7
3.6
V
DC input voltage
0
VDD
V
VIL
Input low voltage – ICH type
0
0.3*VDD
V
VIH
Input high voltage – ICH type
0.7*VDD
VDD
V
VH
Input hysteresis
0.4
V
IL
Input leakage current
5
µA
VOL
Output low voltage
@ IOL = 0.1 mA
0.2
V
VOL
Output low Voltage
RES0, RES1, RES2
@ IOL = 8 mA
D7 – D0, RDY
@ IOL = 4 mA
All other outputs
@ IOL = 2 mA
0.5
V
VOH
Output high voltage
@ ION = – 0.1 mA
VDD – 0.2
VOH
Output high Voltage
RES0, RES1, RES2
@ IOL = 8 mA
D7 – D0, RDY
@ IOL = 4 mA
All other outputs
@ IOL = 2 mA
VDD – 0.8
V
VO
Voltage applied to tristate output
0
VDD
V
Tristate output leakage current
5
µA
Topr
Operating Temperature
– 40
85
0
C
IDD
Operating Current consumption @ 3 V
@ CLKIN frequency = 2 MHz
@ CLKIN frequency = 4 MHz
Operating Current consumption @ 3.3 V
@ CLKIN frequency = 8 MHz
All inputs connected to CMOS outputs,
All outputs driving CMOS inputs.
0.25
0.30
0.45
mA