IT
GB
DE
FR
ES
- 26 -
C13062
111.
fm
English
4 - Undo the nut
(E)
.
5 - Undo the screws
(F)
and remove the bushes
(G)
.
6 - Unscrew and replace the threaded rod
(H)
.
7 - Set the bush
(L)
at the distance as shown in the
figure.
8 - Reassemble the bushes
(G)
and tighten the
screws
(F)
.
9 - Fully tighten the nut
(E)
.
Important
Lubricate the threaded rod (H) with Teflon
grease (Tecnolube Seal RHEOLUBE 368F,
OKS 265, etc.).
10 - Replace the control panel
(D)
and the knob
(B)
on completion of the operation.
Important
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work. Never dump non-biodegradable ma-
terials, lubricating oils and non-metallic
components (rubber, PVC, resins, etc.) in
the environment. Dispose of them in ac-
cordance with the relevant legal require-
ments.
DECOMMISSIONING THE APPLIANCE
IDM-39616003300.tif
F
G
F
G
H
E
L