IT
GB
DE
FR
ES
C13062
111.
fm
- 9 -
English
Lighting
Important
Before proceeding with this operation
check that the well is not raised and resting
firmly on fixed part of appliance.
1 - Turn on the gas supply tap.
2 - Turn the knob
(A)
clockwise (pos.
1
) to turn on
the electricity supply.
The mains light
(C)
comes on.
3 - Press the knob
(B)
and turn it anti-clockwise
(pos.
3
) to light the pilot light.
Keep the knob pressed for about 15 sec. to prime
the thermocouple.
4 - Press the knob
(B)
and turn it anti-clockwise
(pos.
4
) to light the burner.
5 - Turn the knob
(A)
clockwise (pos.
1
) to the tem-
perature required.
The temperature light
(D)
comes on. The light
goes out once the temperature is reached.
SWITCHING THE BURNER ON AND OFF
Turning off
1 - Press the knob
(B)
and turn it clockwise (pos.
5
)
to turn off the burner.
The pilot light will remain on to allow the burner
to be re-lit.
2 - Press the knob
(B)
and turn it clockwise (pos.
6
)
to turn off the pilot light.
3 - Turn the knob
(A)
clockwise (pos.
2
) to turn off
the electricity supply.
The mains light
(C)
goes out.
4 - Turn off the gas supply tap.
5 - Cut off the mains electricity supply using the ap-
pliance's master switch.
IDM-39616000700.tif
1
2
A
C
D
A
IDM-39616000800.tif
B
B
5
4
6
3