![Angelo Po 191BR1G Use And Installation Manual Download Page 55](http://html.mh-extra.com/html/angelo-po/191br1g/191br1g_use-and-installation-manual_2943543055.webp)
IT
GB
DE
FR
ES
C13062
111.
fm
- 25 -
English
To carry out this operation,
proceed as follows.
1 - Turn off the gas supply
tap.
2 - Remove the knob
(B)
.
3 - Undo the screws
(C)
and remove the control
panel
(D)
.
4 - Unscrew the union
(E)
.
5 - Remove the nozzle
(F)
and replace it with the
one suitable for the
type of gas in use (see
table at back of manu-
al).
6 - Retighten the union
(E)
.
7 - Replace the control panel
(D)
and the knob
(B)
on completion of the operation.
REPLACEMENT OF THE PILOT LIGHT INJECTOR
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Remove the knob
(B)
.
3 - Undo the screws
(C)
and remove the control
panel
(D)
.
REPLACING THE WELL TILTING DEVICE
B
IDM-39616002700.tif
C
C
D
F
E
B
C
D
C
IDM-39616002100.tif