![Angelo Po 191BR1G Use And Installation Manual Download Page 43](http://html.mh-extra.com/html/angelo-po/191br1g/191br1g_use-and-installation-manual_2943543043.webp)
IT
GB
DE
FR
ES
C13062
111.
fm
- 13 -
English
The appliance has been tested before being put
into service.
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and malfunctions which might occur during
use.
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
FAULT
6
TROUBLESHOOTING
Faults
Causes
Remedies
Smell of gas.
Occasional leak because flame has
gone out.
Turn off the gas supply tap and
ventilate the room.
The pilot light does not ignite.
The spark ignition devices are not
working.
Check that the ignition devices are
in good working order
Light by hand with a naked light
Important
Contact the after-sales service
Air in pipelines due to long period
out of use.
Make more attempts
to light the flame.
The pilot light goes out.
The thermocouple has not warmed
up enough.
Make more attempts
to light the flame.
The pilot light ignites but the burner
remains off.
Check the condition
of the thermostat and
activate any ignition
enabling device.
The flame is yellow.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Important
Contact the after-sales service
Burner control knob is stiff.
Gas valve malfunction.
Important
Contact the after-sales service
No water delivered.
Filler solenoid valve faulty.
Check the solenoid
valve connection
Important
Contact the after-sales service
Filling switch malfunction.
Important
Contact the after-sales service
Well raised or not resting on fixed
part of appliance.
Check that the well is not raised or
not resting firmly on fixed part of
appliance.