To carry out this operation,
proceed as follows.
1 - Turn off the gas supply
tap.
2 - Remove the knob
(B)
.
3 - Undo the screws
(C)
and remove the control
panel
(D)
.
4 - Undo the locking
screw
(E)
.
5 - Set the bush
(F)
at the
distance as shown in
the figure.
6 - Tighten the screw
(E)
.
After making the setting, seal the screw with
paint.
7 - Replace the control panel
(D)
and the knob
(B)
on completion of the operation.
ADJUSTING BURNER PRIMARY AIR (291BR1G - 291BR2G - 291BR3G)
Important
This adjustment must be made with the well
completely lowered.
To carry out this operation, proceed as follows.
1 - Remove the knob
(B)
.
2 - Undo the screws
(C)
and remove the control
panel
(D)
.
ADJUSTING THE WELL LIMIT STOP MICROSWITCH
B
IDM-39616002300.tif
C
C
D
E
F
42±1
mm
B
C
D
C
IDM-39616002100.tif