CONTROL I/O INPUT FUNCTIONS
INF-01: Capability of Input Terminal A1
INF-02 : Capability of Input Terminal A2
INF-03: Capability of Input Terminal A3
INF-04: Capability of Input Terminal A4
INF-05: Capability of Input Terminal A5
INF-06: Capability of Input Terminal A6
Setting
Default
Parameter Description
0 No
capability
1 Zero
2 Tare
3 Batch
start
4 Emergency
stop
5 Discharge
start
6 Key
enable
7
Automatic free fall command
8
Disable thumbwheel switch read
9 Clear
tare
10 Accumulation
command
11
Cancel previous accumulation
12 Clear
accumulation
13 Hold
1 2 3 4 5 6
14
Print command for manual print
User’s settings
CONTROL I/O OUTPUT FUNCTIONS
OUTF-01: Capability of Output Terminal B1
OUTF-02: Capability of Output Terminal B2
OUTF-03: Capability of Output Terminal B3
OUTF-04: Capability of Output Terminal B4
OUTF-05: Capability of Output Terminal B5
OUTF-06: Capability of Output Terminal B6
OUTF-07: Capability of Output Terminal B7
OUTF-08: Capability of Output Terminal B8
Setting
Default
Parameter Description
0 No
capability
1
Zero range
2 Underlimit/
Hi-Hi
3 Overlimit/Hi
4
Full flow/ Full/ Go
5
Medium flow/ Lo
6 Dribble
flow/
Lo-Lo
7 Discharge
8 Batch
Finish
9 Stability
10 Online
11 Weighing
sequence
running
12 Weighing
sequence
error
13 Input
acknowledge
14
Zero range error
15 Weighing
capacity
overflow
1 2 3 4 5 6 7 8
16 Low
battery
User’s settings