![AND Weighing Indicator AD-4401 Instruction Manual Download Page 57](http://html1.mh-extra.com/html/and/weighing-indicator-ad-4401/weighing-indicator-ad-4401_instruction-manual_2941326057.webp)
55
OUTPUT TERMINAL FUNCTION (OUTF-01 TO OUTF-08)
Output terminals B1 through B6 can be optionally selected with the “general functions OUTF-01 through OUTF-08.”
(See 6-4.)
Set value
Function Name
Description
0 No
function
N/A
1
Zero range
Turned on when the gross is close to the zero range.
Underlimit
In case of Normal batching/Loss-in-weight
2
Hi-Hi
In case of check weighing
Overlimit
In case of Normal batching/Loss-in-weight
3
Hi
In case of check weighing
Full flow
In case of normal batching
Full
In case of Loss-in-weight
4
Go
In case of check weighing
Medium flow
In case of Normal batching /
Loss-in-weight
5
Lo
In case of check weighing
Dribble flow
In case of Normal batching /
Loss-in-weight
6
Lo-Lo
In case of check weighing
7 Discharge
8 Batch
finish
Exclusive for built-in automatic program
Functioning differs depending
on the weighing mode
CALF-14. See CHAPTER 7
WEIGHING SEQUENCE.
9
Motion detection
Turned on when the weight value is stabilized.
10
Online
Turned on in case of the normal mode
11 Weighing
sequence
running
Turned on when waiting for an input of the
loading signal.
12
Weighing sequence error
Turned on when a weighing sequence
error occurs.
Exclusive for built-in automatic
program
13
Input acknowledge
Turned on for 0.5 second after detecting a rise edge of the input terminal.
14
Zero error
Turned on when zeroing was performed and could not be accepted because it
was beyond the condition.
15
Capacity overflow
Turned on when the gross overflows.
16
Low battery
Turned on when the memory backup battery has run out.
Note 1:
Output ON refers to the state that the open collector circuit for each output and output COM have power
continuity. (See 8-1 for circuit description)
In order to prevent malfunctioning, each output terminal is turned off in the non-normal mode such as
“before displaying the weight after power-on” or “OFF mode.”
Summary of Contents for Weighing Indicator AD-4401
Page 1: ...AD 4401 WEIGHING INDICATOR 1386 2A IE...
Page 42: ...40...
Page 87: ...85 APPENDIX DIMENSIONS AD 4401 OP 05...
Page 88: ...86...
Page 89: ...87...
Page 90: ...88...