Connector J7: REM B : Power and RS485 communications to Remote Sensors
Connector
Weidmuller BL3.5 5 way
Mating
Connector
Accepts wire size 0.5 to 1.5mm2 or ferrules, and provides screwdriver terminal
for each core.
Pin No
Service
Signal
Comments
1
Power to Remote
Sensor
+24V
2
RS485
Communications to
Remote Sensor
+
3
-
4
Screen
5
Power to Remote
Sensor
0V
Connector J9: REM C : Power and RS485 communications to Remote Sensors
Connector
Weidmuller BL3.5 5 way
Mating
Connector
Accepts wire size 0.5 to 1.5mm2 or ferrules, and provides screwdriver terminal
for each core.
Pin No
Service
Signal
Comments
1
Power to Remote
Sensor
+24V
2
RS485
Communications to
Remote Sensor
+
3
-
4
Screen
5
Power to Remote
Sensor
0V
Please note that Connector J6 is used either for the first REM in a system, or for all REMs when the
REMs are ‘daisy
-
chained’ together (such as a chamber monitoring system with a REM1 and REM2).
In systems where each REM has its own dedicated channel back to the operator console,
Connector J7 is used for a second sensor and J9 for a third sensor if fitted.