Settings Menu
19
Modero G5 Touch Panels - Configuration and Programming
Calibrating the Light Sensor
When the touch panel is installed for the first time, the light sensor should be calibrated to the room’s maximum ambient
light condition. This calibration setting will be saved until the panel’s system settings are reset.
To calibrate the light sensor from the
Settings
pages:
1.
From the
Sensor Settings
page, click the
Light Sensor Calibration
selection.
2.
Give the panel 10 seconds to calibrate the room's ambient light level. The indicator next to the button will run a
rotating circle while calibration is in progress.
Sensors page options
Motion Detection:
• The blue bar within the slide bar shows the current motion sensor reading.
• The slide bar sets the motion sensor threshold.The threshold controls when a
motion sensor channel is on.
• The “walk” icon shows bars on either side when the threshold is crossed (FIG. 30).
Wake on Motion Sense:
Click this checkbox to wake up the panel if any motion detected crosses the threshold
set by the Motion Detection slide bar.
Wake on Motion Test:
This selection only be enabled if
Wake Panel On Motion Sense
is enabled.
Pressing the test button will initiate a test mode where the display will go to sleep and
wait for motion to turn it on.
It can be used to test your current Motion Detection threshold value.
Light Sensor Level Value:
• The blue bar within the slide bar displays the current light sensor reading.
• The slide bar indicates the light sensor threshold.
• The threshold controls when a Light Sensor Channel Code press will be generated.
Light Sensor Calibration:
Click this button to perform a calibration on the light sensor.
Light Sensor Level Port:
This displays the current level port being used by the light sensor. The default is 1.
Light Sensor Level Number:
This displays the current level being used by the light sensor. The default is 0.
Light Sensor Channel Port:
This displays the current channel port being used by the light sensor. The default is 1.
Light Sensor Channel Number:
This displays the current channel being used by the light sensor. The default is 0.
Motion Sensor Channel Port:
This displays the current channel port being used by the motion sensor.
The default is 1.
Motion Sensor Channel Number: This displays the current channel being used by the motion sensor. The default is 0.
Sensor Version:
This displays the current sensor version, if applicable.
Light and motion sensor ports, levels, and channels are configured in TPDesign 5.
For more information on configuring light and motion sensors, please refer to the
TPDesign 5 Operation/Reference Guide
, available at www.amx.com.
Summary of Contents for Modero G5
Page 58: ...Settings Menu 48 Modero G5 Touch Panels Configuration and Programming ...
Page 62: ...Gestures 52 Modero G5 Touch Panels Configuration and Programming ...
Page 66: ...MXA MP and MXA MPL Programming 56 Modero G5 Touch Panels Configuration and Programming ...
Page 138: ...Appendix B Bargraph Functions 128 Modero G5 Touch Panels Configuration and Programming ...