Network Configuration
66
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
Factory Default Parameters
Factory Default Parameters
Parameter
Value
MAC Address
As set in Factory
Serial Number
As set in Factory
Ethernet Mode
Auto (i.e., speed, duplex, both, auto)
IP Addressing Mode
DHCP
IP Address (for static mode)
192.168.1.2
Netmask (for static mode)
255.255.255.0
Gateway (for static mode)
192.168.1.1
DNS1 (for static mode)
192.168.1.1
DNS2 (for static mode)
192.168.1.1
DNS3 (for static mode)
192.168.1.1
DNS Domain
amx.com
Hostname
Last 7 digits of the serial number
Master Connection Mode
NDP - For details, see page 116.
Master URL
(for TCP and UDP URL modes)
“” (blank)
Master Connection Port Number
(for TCP and UDP URL modes)
1319
Friendly-Name
“” (blank)
Note:
If the Friendly Name is non-blank, both Friendly Name and Location are
concatenated to make NDPSTRING2, otherwise NDPSTRING2 is generated
from the unit’s serial number.
Location
“” (blank)
Stored MAC Address of Master
(for NDP binding)
00:00:00:00:00:00
ICSP Device Number
0 (0 = receive dynamic device number from Master)
System Number
0
Telnet Port
23
A value of 0 disables the Telnet server. Telnet is enabled by default.
SET BAUD
9600, N, 8, 1
CTOF Time
5 (0.5 seconds)
CTON Time
5 (0.5 seconds)
Receivers Only
VIDOUT_ASPECT_RATIO STRETCH
VIDOUT_RES_REF
1280x1024,60 (for Manual Mode)
AUDOUT_FORMAT All
Transmitters Only
VIDIN_AUTO_SELECT
ENABLE
VIDIN_FORMAT
HDMI (on Port 7), VGA (on Port 8)
VIDIN_RES_AUTO
ENABLE
VIDIN_RES_REF
1280x1024,60
VIDIN_PREF_EDID
1920x1080p,60
VIDIN_EDID
MIRROR OUT 1 (on Port 7), ALL RESOLUTIONS (on Port 8)
VIDIN_HDCP
ENABLE
VIDIN_VSHIFT
0
VIDIN_HSHIFT
0
VIDIN_PHASE
0
AUDIN_FORMAT_AUTO
ENABLE
AUDIN_FORMAT
Analog