3.3 Order code of Temposonics
®
RFV
a Sensor model
R F V
Flexible rod
b Design
B
Base unit
M
Threaded fl ange M18×1.5-6g (standard)
S
Threaded fl ange ¾"-16 UNF-3A (standard)
Section
c
is intentionally omitted.
d Stroke length
X X X X X M
00150…20000 mm
Stroke length (mm)
Ordering steps
150… 1000 mm
50 mm
1000… 5000 mm
100 mm
5000…10000 mm
250 mm
10000…15000 mm
500 mm
15000…20000 mm
1000 mm
X X X X X U
0006.0…0787.0 in.
Stroke length (in.)
Ordering steps
6… 40 in.
2 in.
40…197 in.
4 in.
197…394 in.
10 in.
394…591 in.
20 in.
591…787 in.
40 in.
Non standard stroke lengths are available;
must be encoded in 5 mm/0.1 in. increments
.
e Number of magnets
0 X
01…02 Position(s) (1…2 magnet(s))
f Connection type
Connector
D 3 4
M12 male connector (5 pin)
D 6 0
M16 male connector (6 pin)
Angled cable outlet
E X X
XX m/ft. PVC cable (part no. 530 032)
E01…E30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
specifi cations
G X X
XX m/ft. FEP cable (part no. 530 157)
G01…G30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
specifi cations
L X X
XX m/ft. PUR cable (part no. 530 052)
L01…L30 (1…30 m/3…99 ft.)
(Note the temperature range of the cable!)
See “Frequently ordered accessories” for cable
specifi cations
U X X
XX m/ft. Silicone cable (part no. 530 176)
U01…U30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
specifi cations
Straight cable outlet
H X X
XX m/ft. PUR cable (part no. 530 052)
H01…H30 (1…30 m/3…99 ft.)
(Note the temperature range of the cable!)
See “Frequently ordered accessories” for cable
specifi cations
R X X
XX m/ft. PVC cable (part no. 530 032)
R01…R30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
specifi cations
T X X
XX m/ft. PTFE cable (part no. 530 112)
T01…T30 (1…30 m/3…99 ft.)
See “Frequently ordered accessories” for cable
specifi cations
Encode in meters if using metric stroke length.
Encode in feet if using US customary stroke length.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
R F V
1
a
b
d
e
f
g
h
i
j
k
l
optional