Controlling design dimensions are in millimeters and measurements in ( ) are in inches
Multi-position measurement
The minimum distance between the magnets is 75 mm (3 in.).
Fig. 42: Minimum distance between magnets for multiposition measurement (RH5, RP5,
RFV, RDV)
NOTICE
Use magnets of the same type for multiposition measurement.
Do not go below a minimal distance of 75 mm (3 in.) between the
magnets for differential measurement. Contact Temposonics if you
need a magnet distance, which is smaller than 75 mm (3 in.).
RP5 with U-magnets
≥ 75 (≥ 3)
RP5 with magnet sliders
≥ 75 (≥ 3)
RP5 with block magnets
≥ 75 (≥ 3)
RH5 & RFV with ring magnets/U-magnets
≥ 75 (≥ 3)
RH5 & RFV with block magnets
≥ 75 (≥ 3)
RDV with ring magnets/U-magnets
≥ 75 (≥ 3)
RDV with block magnets
≥ 75 (≥ 3)