Temposonics
®
R-Series
V
Analog
Operation Manual
I 32 I
RFV-B with block magnet
Sensor electronics housing
Reference edge of mounting
Start position
58.5 (2.3)
End position
See table
RFV-M/-S with block magnet
Sensor electronics housing
Reference edge of mounting
Start position
48.5 (1.91)
End position
See table
Stroke length
Tolerance of total length Dead zone
Up to 7620 mm
(300 in.)
+8 mm (0.31 in.)/
−5 mm (0.20 in.)
94 mm (3.70 in.)
Up to 10,000 mm
(393.70 in.)
+15 mm (0.59 in.)/
−15 mm (0.59 in.)
100 mm (3.94 in.)
Up to 15,000 mm
(590.55 in.)
+15 mm (0.59 in.)/
−30 mm (1.18 in.)
120 mm (4.72 in.)
Up to 20,000 mm
(787 in.)
+15 mm (0.59 in.)/
−45 mm (1.77 in.)
140 mm (5.51 in.)
RDV-S with ring magnet/U-magnet
Reference edge of mounting
Start position
21.4 (0.84)
End position
63.5 (2.5)
RDV-M/-T with ring magnet/U-magnet
Reference edge of mounting
Start position
51 (2.01)
End position
63.5/66* (2.5/2.6*)
* Stroke length > 5000 mm (196.9 in.)
RDV-C/-D with ring magnet/U-magnet
Reference edge of mounting
Start position
51 (2.01)
* Stroke length > 5000 mm (196.9 in.)
RDV-S with block magnet
Reference edge of mounting
Start position
21.4 (0.84)
End position
63.5 (2.5)
RDV-M/-T with block magnet
Reference edge of mounting
Start position
51 (2.01)
End position
63.5/66* (2.5/2.6*)
* Stroke length > 5000 mm (196.9 in.)
RDV-C/-D with
block magnet
Reference edge of mounting
Start position
51 (2.01)
* Stroke length > 5000 mm (196.9 in.)
End position
63,5/66*
End position
63,5/66*
NOTICE
On all sensors, the areas left and right of the active stroke length are
provided for null and dead zone. These zones should not be used for
measurement, however the active stroke length can be exceeded.
Fig. 39: Start- and end positions of magnets for RFV with block magnet
Fig. 40: Start- and end positions of magnets for RDV with ring- and U-magnets
Fig. 41: Start- and end positions of magnets for RDV with block magnet
Controlling design dimensions are in millimeters and measurements in ( ) are in inches