Temposonics
®
R-Series
V
Analog
Operation Manual
I 31 I
Start- and end positions of the position magnets
Consider the start and end positions of the position magnets during
the installation. To ensure that the entire stroke length is electrically
usable, the position magnet must be mechanically mounted as
follows.
Fig. 36: Start- and end positions of magnets for RP5
Fig. 37: Start- and end positions of magnets for RH5
Fig. 38: Start- and end positions of magnets for RFV with ring- and U-magnets
RP5 with magnet slider “S”, “N”, “V”, “G”
Sensor electronics housing
Reference edge of mounting
Start position
12 (0.47)
End position
82/87* (3.23/3.43*)
* Stroke length > 5000 mm (196.9 in.)
RP5 with U-magnet
Reference edge of mounting
Sensor electronics housing
Start position
28 (1.1)
End position
66/71* (2.6/2.8*)
* Stroke length > 5000 mm (196.9 in.)
RP5 with block magnet
Reference edge of mounting
Sensor electronics housing
* Stroke length > 5000 mm (196.9 in.)
End position
68.5/73.5* (2.7/2.9*)
Start position
25.5 (1)
RH5 with ring magnet/U-magnet
Sensor electronics housing
Reference edge of mounting
Start position
51 (2.01)
End position
63.5/66* (2.5/2.6*)
* Stroke length > 5000 mm (196.9 in.)
RH5 with block magnet
Sensor electronics housing
Reference edge of mounting
Start position
48.5 (1.91)
End position
66/68.5* (2.6/2.7*)
* Stroke length > 5000 mm (196.9 in.)
RFV-B with ring magnet/U-magnet
Sensor electronics housing
Reference edge of mounting
Start position
61 (2.4)
End position
See table
RFV-M/-S with ring magnet/U-magnet
Sensor electronics housing
Reference edge of mounting
Start position
51 (2.01)
End position
See table
Stroke length
Tolerance of total length Dead zone
Up to 7620 mm
(300 in.)
+8 mm (0.31 in.)/
−5 mm (0.20 in.)
94 mm (3.70 in.)
Up to 10,000 mm
(393.70 in.)
+15 mm (0.59 in.)/
−15 mm (0.59 in.)
100 mm (3.94 in.)
Up to 15,000 mm
(590.55 in.)
+15 mm (0.59 in.)/
−30 mm (1.18 in.)
120 mm (4.72 in.)
Up to 20,000 mm
(787 in.)
+15 mm (0.59 in.)/
−45 mm (1.77 in.)
140 mm (5.51 in.)
Controlling design dimensions are in millimeters and measurements in ( ) are in inches