Page 45
EVACU ELITE
INSTALLATION, COMMISSIONING AND USER MANUAL
Dual 25-watt amplifier card, located in rack 1, slots 5 and 6. To view the status of this card,
select the Dual 25-watt amplifier card Icon
50-watt amplifier card, located in rack 1, slots 7 and 8. A second card if fitted in slots 9 and
10. To view the status of this card select the 50-Watt amplifier card Icon
Dual loop EIS line card, located in rack 1, slot 16. To view the status of this card, select the
Dual loop EIS line card Icon.
Graphical user Interface – located on the inner door. To view the status of this card, select
the Graphical user interface Icon
Power supply – located beneath rack 1. To view the status of this card, select the Power
supply Icon.
6.3.1 Distribution CPU card
The Distribution CPU card has 4 inputs and 3 outputs (refer to section 4.2.4.1). The status screen for the
Distribution CPU card shows the module status and the status of the 4 inputs as follows:
Figure 6-3 Distribution CPU card status screen
The following explains the content of the screen
Display the previous module in the node
Display the next module in the node
Display the inputs – inputs are currently displayed as the icon is highlighted
Press to display the outputs. The Distribution CPU card has 3 outputs