![AMOG D'AVINO 120TW User Manual Download Page 111](http://html.mh-extra.com/html/amog/davino-120tw/davino-120tw_user-manual_2933765111.webp)
DAVINO 120TW - USER AND MAINTENANCE MANUAL Rev.04
- Pag. 110
FAILURE
CAUSE
REMEDY
IRREGULAR
STEERING ACTION
Steering type selector
Check electrical connections
Hydraulic filter
replace
Servoe-drive tube
Check for any leakage/air suction
GEAR LEVER
INOPERABLE
Electrical disconnection
Test LED lamp on the hydrostatic
pump solenoid and on the
hydrostatic motor
Electrical disconnection
Check fuse n. 18
Check solenoid coil
Motor and pump
INSUFFICIENT
BRAKING
Pedal disconnect
check
Insufficient brake oil
check
Brake fluid leakage
check
Loose tie rods
adjust
DISTRIBUTOR
LEVERS HARD TO
MOVE
Hydraulic oil dirty
contact specialized technicien