Industry Cellular Gateway
Create / Edit Digital Input (DI) Profile Rule
(DI/DO support required)
Setup the Digital Input (DI) Profile rules. It supports up to a maximum of 10 profiles.
When
Add
button is applied, the
Digital Input (DI) Profile Configuration
screen will appear.
Digital Input (DI) Profile Configuration
Item
Value setting
Description
DI Profile
Name
1. String format
2. A Must filled setting
Specify the DI Profile Name.
Value Range
:
-1 ~ 32 characters.
Description
1. Any text
2. An Optional setting
Specify a brief description for the profile.
DI Source
ID1
by default
Specify the DI Source. It could be
ID1
or
ID2
.
The number of available DI source could be different for the purchased product.
Normal Level
Low by default
Specify the Normal Level. It could be
Low
or
High
.
Signal Active
Time
1. Numberic String format
2. A Must filled setting
Specify the Signal Active Time. It could be from 1 to 10 seconds.
Value Range
:
1 ~ 10 seconds.
Check Interval
1. Numberic String format
2. A Must filled setting
3. ‘0’ is set by default
Specify the check interval for the DI event. It could be from 0 to 86400 seconds.
If the event condition keeps active for a long time interval, the gateway will
send repeated notify events for each check interval.
Value Range
:
0 ~ 86400 seconds.
Note :
To prevent receving too much notify event for the same situation, you
can adjust the check interval to a proper one for your application.
Profile
The box is unchecked by
default.
Click
Enable
box to activate this profile setting.
Save
NA
Click the
Save
button to save the configuration.
352