Industry Cellular Gateway
Item
Value setting
Description
Source IP
A Must fill setting
Select
Specific IP Address
to only allow an IP address of the allowed Master to
access the attached Slave(s).
Select
IP Range
to only allow a set range of IP addresses of the allowed Master
to access the attached Slave(s).
Select
IP Address-based Group
to only allow pre-defined group of IP address of
the allowed Master to access the attached Slave(s).
Note: group must be pre-defined before this selection become available. Refer
to
Object Definition > Grouping > Host grouping
. You may also access to
create a group by the Add Rule shortcut button. Setting done through the Add
Rule button will also appear in the Host grouping setting screen.
Then check
Enable
box to enable this rule.
Enable
Unchecked by default
Check the
Enable
box to enable this rule.
Modbus Priority Definition
Message Buffering must be enabled to prioritize Master request queue to transmit to Modbus Slave as
mentioned in the above. Click the
Edit
button to fill in the priority settings.