Industry Cellular Gateway
field bus device status monitoring, digital sensors detection controlling, and so on. All of such management
and notification function can be realized effectively via the Event Handling feature.
The following is the summary lists for the provided profiles, and events:
(
Note
: The available profiles and events could be different for the purchased product.)
Profiles (Rules):
•
SMS Configuration and Accounts
•
Email Accounts
•
Digital Input (DI) profiles
•
Digital Output (DO) profiles
•
Modbus Managing Event profiles
•
Modbus Notifying Event profiles
Managing Events:
•
Trigger Type: SMS, SNMP Trap, and Digital Input (DI).
•
Actions: Get the Network Status; or Configure the LAN/VLAN behavior, WIFI behavior, NAT
behavior, Firewall behavior, VPN behavior, System Management, Administration, Digital Output
behavior, and connected Modbus devices.
Notifying Events:
•
Trigger Type: Digital Input, Power Change, Connection Change (WAN, LAN & VLAN, WiFi, DDNS),
Administration, Modbus, and Data Usage.
•
Actions: Notify the administrator with SMS, Syslog, SNMP Trap or Email Alert; Change the status
of connected Digital Output or Modbus devices.
To use the event handling function, First of all, you have to enable the event management setting and
configure the event details with the provided profile settings. You can create or edit pre-defined profiles for
individual managing / notifying events. The profile settings are separated into several items; they are the SMS
Account Definition, Email Service Definition, Digital Input (DI) Profile Configuration, Digital Output (DO) Profile
Configuration, and Modbus Definition.
Then, you have to configure each managing / notifying event with identifying the event’s trigger condition, and
the corresponding actions (reaction for the event) for the event. For each event, more than one action can be
activated simultaneously.
348