Overview
Asterion DC Series
1-20
1.2.15
Protection Function Characteristics
Function
Characteristic
Output Overvoltage Protection
(OVP)
Programmable to 110% of full-scale output voltage;
exceeding OVP threshold results in shutdown of output.
Output Current Limit Protection
User-selectable fold back mode CV/CC/CP or CV or CC or CP
models.
In CV/CC/CP mode, output current or power is regulated to
setpoint on reaching limit.
In CV mode, on reaching current or power limits results in
shutdown of output;
In CC mode, on reaching voltage or power limits results in
shutdown of output;
In CP mode, on reaching voltage or current limits results in
shutdown of output;
In CV or CC or CP mode, shutdown delay on reaching the limit is
programmable from 100 ms to 5 s.
AC Input Overcurrent Protection
Internal fuses in each phase for fault isolation; not user
replaceable
AC Input Undervoltage Protection
Automatic shutdown for insufficient AC input voltage
AC Input Transient Protection
Protection to withstand EN61326-1, Class-A surge levels
Overtemperature Protection (OTP)
Internal temperature monitors cause shutdown of output if
temperature thresholds are exceeded
1.2.16
Environmental Specifications
Parameter
Specification
Operating Temperature
0°C to 50°C (32° F to 104° F), 100% load
Storage Temperature
-30°C to 85°C ( -22°F to 185° F)
Altitude
3000 m (10,000 ft), output current derating 2%/100m or T
ambient
1⁰C/100m above 2000m
Operating Humidity
20-90 %, non-condensing
Storage Humidity
10-95 %, non-condensing
Vibration
MIL-PRF-28800F, Class 3; 5-500 Hz per Paragraph 4.5.5.3.1
Shock
MIL-PRF-28800F, Class 3; 30G half-sine with 11ms duration per
Paragraph 4.5.5.4.1
Transportation Integrity
ISTA 2A-2011 and ISTA 3B-2017 Test Procedures
Summary of Contents for Sorensen Asterion DC Series
Page 1: ...M330460 01 Rev D 1 Asterion DC Series Operation Manual...
Page 2: ...Contents Asterion DC Series ii This page intentionally left blank...
Page 23: ...Asterion DC Series Overview M330460 01 Rev D 1 7 Figure 1 2 Auto range Models Characteristics...
Page 38: ...Overview Asterion DC Series 1 22 This page intentionally left blank...
Page 43: ...Asterion DC Series Installation M330460 01 Rev D 2 5 Figure 2 1 Rack mounting 1U Models...
Page 44: ...Installation Asterion DC Series 2 6 Figure 2 2 Rack Mounting 2U Chassis...
Page 49: ...Asterion DC Series Installation M330460 01 Rev D 2 11 Figure 2 5 Rear Panel View 1U Models...
Page 50: ...Installation Asterion DC Series 2 12 Figure 2 6 Rear Panel View 1U Models w EtherCAT Option...
Page 52: ...Installation Asterion DC Series 2 14 Figure 2 8 Rear Panel View 2U Chassis...
Page 83: ...Asterion DC Series Installation M330460 01 Rev D 2 45 This page intentionally left blank...
Page 84: ......
Page 144: ...Calibration Asterion DC Series 3 60 Figure 3 114 Parallel Connection 3 Chassis...
Page 148: ...Calibration Asterion DC Series 3 64 Figure 3 117 Series Connection...
Page 149: ...Asterion DC Series Calibration M330460 01 Rev D 3 1 This page intentionally left blank...
Page 151: ...Asterion DC Series Calibration M330460 01 Rev D 4 3 This page intentionally left blank...
Page 152: ......
Page 157: ...M330460 01 www powerandtest com This page intentionally left blank...