Overview
Asterion DC Series
1-10
1)
Unit can operate at
1.7 kW if powered by greater than or equal to 20 A of input current inlet and ambient
does not exceed 40°C.
2)
Unit can operate at
5 kW if powered by greater than or equal to 30 A of input current inlet and ambient
does not exceed 40°C
3)
For 3.4kW performance at single phase operation for 90-145Vac or 180-200Vac limits, contact to
factory for more details.
1.2.5
AC input current
Output Power
derating
characteristics
with AC input
voltage
Model
Size
Rated
Output
Power
Model
1-Phase
Low Input
Range
(90 -145 V
AC)
1-Phase
High
Input
Range
(180-
200VAC)
1-Phase
High
Input
Range
(200- 264
VAC)
3-Phase
(180 -264
VAC)
3-
Phase
(342 -
440
VAC)
3-
Phase
(432 -
528
VAC)
Models with “C” Input
Models
with
“D”
Input
Models
with
“E”
Input
1U
1.7 kW
14.4A
1
11.7A
10A
6A
3.5A
3A
3.4 kW
14.2A
1,3
20A
3
20A
12A
7A
5.8A
5.0 kW
20A
23A
20A
17.8A
10A
8.5A
2U
10.0kW
N/A
N/A
N/A
35A
20A
17A
1)
Unit can operate at
1.7 kW if powered by greater than or equal to 20 A of input current inlet and ambient
does not exceed 40°C.
2)
Unit can operate at
5 kW if powered by greater than or equal to 30 A of input current inlet and ambient
does not exceed 40°C
3)
For 3.4kW performance at single phase operation for 90-145Vac or 180-200Vac limits, contact to
factory for more details.
CAUTION!
Due to Input voltage Line Dropping out of range or phase loss or drop out of range, 1U
models will shut down output voltage and present fault massage on the display. After
clearing fault massage, unit will continue operate within new reduced power limits. If
source of failure back to limits, power cycle required to back to specified power limits.
For 2U models, due to Input voltage Line Drop out of range or phase drop, output will shut
down, display present fault massage and after hold-up time, unit will completely turn off.
1.2.6
Output Power derating characteristics with DC input Voltage
Output Power
derating
characteristics with
DC input voltage
Model
Size
Rated
Output
Power
Model
135-370
VDC (+/-
5%)
200-265
VDC
(+/-5%)
265-370
VDC
(+/-5%)
480-704Vdc
(+/-5%)
1U
1.7 kW
1.7 kW
1.7 kW
1.7 kW
1.7 kW
3.4 kW
1.7 kW
3.4 kW
3.4 kW
3.4 kW
5.0 kW
1.7 kW
3.4 kW
5.0 kW
5.0 kW
2U
10.0kW
N/A
N/A
N/A
10.0kW
Summary of Contents for Sorensen Asterion DC Series
Page 1: ...M330460 01 Rev D 1 Asterion DC Series Operation Manual...
Page 2: ...Contents Asterion DC Series ii This page intentionally left blank...
Page 23: ...Asterion DC Series Overview M330460 01 Rev D 1 7 Figure 1 2 Auto range Models Characteristics...
Page 38: ...Overview Asterion DC Series 1 22 This page intentionally left blank...
Page 43: ...Asterion DC Series Installation M330460 01 Rev D 2 5 Figure 2 1 Rack mounting 1U Models...
Page 44: ...Installation Asterion DC Series 2 6 Figure 2 2 Rack Mounting 2U Chassis...
Page 49: ...Asterion DC Series Installation M330460 01 Rev D 2 11 Figure 2 5 Rear Panel View 1U Models...
Page 50: ...Installation Asterion DC Series 2 12 Figure 2 6 Rear Panel View 1U Models w EtherCAT Option...
Page 52: ...Installation Asterion DC Series 2 14 Figure 2 8 Rear Panel View 2U Chassis...
Page 83: ...Asterion DC Series Installation M330460 01 Rev D 2 45 This page intentionally left blank...
Page 84: ......
Page 144: ...Calibration Asterion DC Series 3 60 Figure 3 114 Parallel Connection 3 Chassis...
Page 148: ...Calibration Asterion DC Series 3 64 Figure 3 117 Series Connection...
Page 149: ...Asterion DC Series Calibration M330460 01 Rev D 3 1 This page intentionally left blank...
Page 151: ...Asterion DC Series Calibration M330460 01 Rev D 4 3 This page intentionally left blank...
Page 152: ......
Page 157: ...M330460 01 www powerandtest com This page intentionally left blank...