DC Output Programming and Measurement Specifications
Programming & Readback (via Front Panel or Remote Digital Interface)
Voltage Output programming accuracy
+/- 0.1% of rated output voltage
Current Output programming accuracy
+/- 0.2% of rated output current
Power Output programming accuracy
+/- 0.3% of rated output power
Overvoltage programming accuracy
+/- 1%, maximum, of rated output voltage
Voltage Output programming resolution
0.012% of full scale
Current Output programming resolution
0.012% of full scale
Power Output programming resolution
0.012% of full scale
Overvoltage programming resolution
0.1% of full scale
Voltage Output Measurement accuracy
+/- 0.1% of rated output voltage
Current Output Measurement accuracy
+/- 0.2% of rated output current
Power Output Measurement accuracy
+/- 0.3% of rated output power
Voltage Output Measurement resolution
0.012% of full scale
Current Output Measurement resolution
0.012% of full scale
Power Output Measurement resolution
0.012% of full scale
Overvoltage Response time
20 ms
1.2.8
DC Output Regulation Characteristics
Constant Voltage Mode
Maximum line regulation
+/- 0.01% of rated voltage
Maximum load regulation
+/- 0.02% of rated voltage
Temperature Drift
+/- 100 PPM / degree Celsius
Stability
+/- 0.05% of rated voltage
Constant Current Mode
Maximum line regulation
+/- 0.05% of rated current
Maximum load regulation
+/- 0.15% of rated current
Temperature Drift
+/- 100 PPM / degree Celsius
Stability
+/- 0.05% of rated current
Constant Power Mode
Maximum line regulation
+/- 0.1% of rated power
Temperature Drift
+/- 100 PPM / degree Celsius
Stability
+/- 0.05% of rated power
Summary of Contents for Sorensen Asterion DC Series
Page 1: ...M330460 01 Rev D 1 Asterion DC Series Operation Manual...
Page 2: ...Contents Asterion DC Series ii This page intentionally left blank...
Page 23: ...Asterion DC Series Overview M330460 01 Rev D 1 7 Figure 1 2 Auto range Models Characteristics...
Page 38: ...Overview Asterion DC Series 1 22 This page intentionally left blank...
Page 43: ...Asterion DC Series Installation M330460 01 Rev D 2 5 Figure 2 1 Rack mounting 1U Models...
Page 44: ...Installation Asterion DC Series 2 6 Figure 2 2 Rack Mounting 2U Chassis...
Page 49: ...Asterion DC Series Installation M330460 01 Rev D 2 11 Figure 2 5 Rear Panel View 1U Models...
Page 50: ...Installation Asterion DC Series 2 12 Figure 2 6 Rear Panel View 1U Models w EtherCAT Option...
Page 52: ...Installation Asterion DC Series 2 14 Figure 2 8 Rear Panel View 2U Chassis...
Page 83: ...Asterion DC Series Installation M330460 01 Rev D 2 45 This page intentionally left blank...
Page 84: ......
Page 144: ...Calibration Asterion DC Series 3 60 Figure 3 114 Parallel Connection 3 Chassis...
Page 148: ...Calibration Asterion DC Series 3 64 Figure 3 117 Series Connection...
Page 149: ...Asterion DC Series Calibration M330460 01 Rev D 3 1 This page intentionally left blank...
Page 151: ...Asterion DC Series Calibration M330460 01 Rev D 4 3 This page intentionally left blank...
Page 152: ......
Page 157: ...M330460 01 www powerandtest com This page intentionally left blank...