Pin
Reference
Type
Functional Description
21
IMON
ANALOG OUT
Monitor signal for output current: 0-10
VDC = 0-100% of full-scale output
current. Minimum recommended load
resistance is 100 KΩ and maximum
load is 20kΩ. Circuit return is pin 22.
22
MON_RTN
ANALOG GND Return for Pin 6, 21, 35.
23
Not Used
Not Used
Not Used
24
TRIG_OUT
DIGITAL OUT
User digital output - cause to be
assigned by user. Output high state
either min 4.5V or voltage on Pin 30
(USER_PWR) minus 1V, whichever
is higher. Maximum current of 0.5A.
25
DIO_OUT1
DIGITAL OUT
Output low for CV and high for CC.
Output high state either min 4.5V or
voltage on Pin 30 (USER_PWR)
minus 1V, whichever is higher.
Maximum current of 0.5A.
26
FAULT_OUT
DIGITAL OUT
High state indicates fault. Output
high state either min 4.5V or voltage
on Pin 30 (USER_PWR) minus 1V,
whichever is higher. Maximum
current of 0.5A.
27
DIO_OUT2
POWER OUT
Output low for CV or CC and high for
CP. Output high state either min 4.5V
or voltage on Pin 30 (USER_PWR)
minus 1V, whichever is higher.
Maximum current of 0.5A.
28
RTN_UPWR
POWER GND
Return for Pin 24, 25, 26, 27.
29
RTN_AUX5
POWER GND
Return for Pin 43 (5V_AUX).
30
USER_POWER
POWER IN
Optional- User can connect between
5V to 24V to control digital
output/relay output voltage. If left
unconnected, digital and relay
outputs have 4.5V high states.
31
ON/OFF_ISO
DIGITAL IN
Isolated remote-control input for
output on/off with a logic signal: a
logic-high, 3.3V to 24V signal will
enable (turn-on) the output of the
supply, and a logic-low signal
disables (turns off) the output. This
control input is optically isolated from
the output power negative terminal of
the power supply (up to 500 VDC).
Signal return is Pin 16 (RTN_HV).
32
Not Used
Not Used
Not Used
Summary of Contents for Sorensen Asterion DC Series
Page 1: ...M330460 01 Rev D 1 Asterion DC Series Operation Manual...
Page 2: ...Contents Asterion DC Series ii This page intentionally left blank...
Page 23: ...Asterion DC Series Overview M330460 01 Rev D 1 7 Figure 1 2 Auto range Models Characteristics...
Page 38: ...Overview Asterion DC Series 1 22 This page intentionally left blank...
Page 43: ...Asterion DC Series Installation M330460 01 Rev D 2 5 Figure 2 1 Rack mounting 1U Models...
Page 44: ...Installation Asterion DC Series 2 6 Figure 2 2 Rack Mounting 2U Chassis...
Page 49: ...Asterion DC Series Installation M330460 01 Rev D 2 11 Figure 2 5 Rear Panel View 1U Models...
Page 50: ...Installation Asterion DC Series 2 12 Figure 2 6 Rear Panel View 1U Models w EtherCAT Option...
Page 52: ...Installation Asterion DC Series 2 14 Figure 2 8 Rear Panel View 2U Chassis...
Page 83: ...Asterion DC Series Installation M330460 01 Rev D 2 45 This page intentionally left blank...
Page 84: ......
Page 144: ...Calibration Asterion DC Series 3 60 Figure 3 114 Parallel Connection 3 Chassis...
Page 148: ...Calibration Asterion DC Series 3 64 Figure 3 117 Series Connection...