AMETEK CTS
OCS 500 N6 series
Manual for Operation
V 5.24
17 / 80
3.2.
Menu structure
Page 0...4
Page 0
Page 1
Page 2
Page 3
Page 4..x
MAIN MENU
F1
Damped Osc. 100kHz
IEC 61000-4-18
F2
Damped Osc. 1MHz
IEC 61000-4-18
F3
Ringwave 100kHz
IEC 61000-4-12
F4
Damped Osc. 100kHz MF IEC 61000-4-10
F5
Damped Osc. 1MHz MF
IEC 61000-4-10
F6
Damped Osc. 1MHz ext.
IEC 60255-26
F7
Service
Damp. Osc.100kHz
IEC 61000-4-18
F1
Quick Start
F2
Standard test routines
F3
User test routines
Quick Start
F1
Start
F2
Change
F3
Continue
Start
Start the test routine
Change
Select all parameters
Continue
Continue the test routine
Damped Osc. 1MHz
IEC 61000-4-18
F1
Quick Start
F2
Standard test routines
F3
User test routines
Standard test routines
Preprogrammed test routines as
per standard requirements
Standard routines
F1
Common Mode
F2
Differential Mode
Standard routines
F1
Level 1
F2
Level 2
F3
Level 3
F7
Manual
Ringwave
IEC 61000-4-12
F1
Quick Start
F2
Standard test routines
F3
User test routines
User test routines
Preprogrammed test routines for
evaluation and design support
User test routines
F1
Synchronous to the mains
F2
Random burst release
F3
Change V
after T by
U
F4
Change polarity after T
User test routines
F1
Start
F2
Change
F3
Continue
Damped Osc. 100Hz MF
IEC 61000-4-10
F1
Quick Start
F2
Standard routines
F3
User test routines
F7
Magnetic field correction factor
Setup Magnetic field
F1
Coil factor Cf [1/m]
Magnetic field factors
Correction factors for magnetic field
antenna
Damped Osc. 1MHz
IEC 60255-26
F1
Quick Start
F2
Standard test routines
F3
User test routines
Damped Osc. 1MHz
IEC 60255-26
Standard test routines
F1
Common Mode 1
F2
Common Mode 2
F3
Differential Mode
Damped Osc. 1MHz
IEC 60255-26
User test routines
F1
Synchronous to the mains
F2
Random burst release
F3
Change V
after T by
U
F4
Change polarity after T
Damped Osc. 1MHz
IEC 60...
F1
Level 1
F2
Level 2
Damped Osc. 1MHz
Ext
IEC 60255-
26
F1
Quick Start
F2
Standard test routines
F3
User test routines
Setup
F1
Change language
F2
LCD backlighting
F3
Interfaces
F4
Beeper
F5
Power
–
on counter
Change language
German or English
LCD backlighting
On, Off or Auto
Interfaces
Select all parameters
Beeper
(on, off)
Power.on counter
Display of
Power on time and Testing time
Service
F1
Addresses
F2
Setup
F3
Change standard levels
F7
Status
Change standard level
F1
set all parameters acc.to
standard
F2
Damped Osc. 100kHz
F3
Damped Osc. 1MHz
F4
Ringwave 100kHz
F5
Damped Osc. 1MHz MF
Change standard level
F1
Level 1
F2
Level 2
F3
Level 3
F4
Level 4
F6
Coupling Diff / Common
mode