4-4 | Model 931S / Model 932S UV Analyzers
Starting the Configurator Software and Establishing
Communication Between the Analyzer and Computer
This section discusses how to start the Configurator Software and estab-
lish communications with the analyzer.
Before beginning, you should
have already installed the analyzer and the Configurator Software, as
explained in Chapter 3.
This section assumes the analyzer is running.
Hazardous Locations
Before proceeding, test the area around the analyzer for explosive
gases and proceed only when the area is found to be safe.
Do not remove the cover of the Explosion-Proof Digital
Communications Port on the front of the Ex d Lower Enclosure, do
not connect a serial cable to the Communications Port, do not open
the Upper/Lower Enclosures, and do not power up/down the analyzer
or computer if there is an explosive gas atmosphere present.
To establish communication between the analyzer and computer:
1. Depending on the type of communication being used, follow one of
the two following setup requirements:
For Modbus Serial communication:
Connect the supplied serial cable between the computer and the
analyzer’s Communications Port on the front of the Lower Enclosure.
Alternatively, connect this cable to the
Remote Service Port
(RS-485,
accessed from connector
J303
on the
Host Controller
board).
For Modbus TCP communication:
Communication between the analyzer and the software will be es-
tablished upon starting the Configurator Software. Proceed to Step 2.
See “Hardware Configuration (Modbus TCP Communication)” in
Chapter 3 for information about hardware requirements.
2. Power up the computer and start the 93XS System 200 Configurator
Software using one of two methods:
• Click
S93xs
from the
Start\All Programs\AMETEK 93XS
Configurator Version #.#
menu.
• Click the
S93xs
icon on the computer’s desktop.
!
WARNING
Summary of Contents for 931S
Page 24: ...1 8 Model 931S Model 932S UV Analyzers This page intentionally left blank...
Page 34: ...2 10 Model 931S Model 932S UV Analyzers...
Page 35: ...Specifications 2 11...
Page 36: ...2 12 Model 931S Model 932S UV Analyzers...
Page 37: ...Specifications 2 13...
Page 38: ...2 14 Model 931S Model 932S UV Analyzers...
Page 39: ...Specifications 2 15...
Page 46: ...2 22 Model 931S Model 932S UV Analyzers...
Page 96: ...3 50 Model 931S Model 932S UV Analyzers This page intentionally left blank...
Page 170: ...4 74 Model 931S Model 932S UV Analyzers This page intentionally left blank...
Page 184: ...5 14 Model 931S Model 932S UV Analyzers This page intentionally left blank...
Page 237: ...Maintenance and Troubleshooting 6 53 Figure 6 14 AC Distribution board P N 100 1771...
Page 238: ...6 54 Model 931S Model 932S UV Analyzers Figure 6 15 Host Controller board P N 100 1757 SW100...
Page 239: ...Maintenance and Troubleshooting 6 55 Figure 6 16 Microcontroller board P N 100 1781 SW400...
Page 250: ...6 66 Model 931S Model 932S UV Analyzers This page intentionally left blank...
Page 263: ...Appendix A Drawings A 7 RS 232 Cable Communications Connections 300 9480...
Page 264: ...A 8 Model 931S Model 932S UV Analyzers Optical Bench Board 100 1662...
Page 265: ...Appendix A Drawings A 9 PMT Buffer Board 100 0140...
Page 268: ...S 2 Model 931S Model 932S UV Analyzers This page intentionally left blank...