As a precursor to operating a superconducting magnet with the Model
430 Programmer and power supply, all of the setup items should be
reviewed and set if necessary with appropriate values for the connected
superconducting magnet.
The figure at left shows an exam-
ple magnet specifications sheet.
Several parameters needed to
operate the magnet are specified.
These values should be entered
into the appropriate setup menu of
the Model 430 Programmer. For
the purposes of this example, the
AMI Model 4Q06125PS power
supply will be assumed, since
rated current for the example mag-
net is 85.6 A.
The Current Limit accessible in the
Protection submenu should be set
to the rated current to prevent
accidental operation of the magnet
above rated field/current. The
magnet specification sheet also
indicates whether a persistent
switch is installed and provides the
recommended heating current. The
persistent switch information is
entered in the Switch submenu.
If your magnet, Model 430
Programmer, and power supply
were purchased as a system from
AMI, the setup menus are preset
by AMI to match the magnet
purchased.
EXCELLENCE IN MAGNETICS AND CRYOGENICS
American Magnetics, Inc.
P.O. Box 2509, 112 Flint Road, Oak Ridge, TN 37831-2509
Phone: (865) 482-1056
Fax: (865) 482-5472
Internet: http://www.americanmagnetics.com E-mail: [email protected]
0$*1(763(&,),&$7,216
AMI JOB #
MAGNET #
TYPE:
6ROHQRLG
MODEL:
&XVWRP
FOR:
$ : &U\R(QJLQHHULQJ/WG
DATE:
0D\
Rated Central Field @ 4.2K
1
---------------------------------
N*
Rated Current ------------------------------------------
DPSV
Max. Field Tested ------------------------------------------
N*
Field to Current Ratio -----------------------------
JDXVVDPS
Homogeneity over a 1 cm DSV --------------------------------
Measured Inductance -----------------------------------
KHQU\V
Charging Voltage ---------------------------------------
YROWV
Axial Clear Bore --------------------------------------
LQFKHV
Overall Length (flange to flange) --------------------
LQFKHV
Maximum Outside Diameter ------------------------------
LQFKHV
Weight ---------------------------------------------------
OEV
Recommended Persistent Switch Heater Current ---------------
P$
Persistent Switch Heater Nominal Resistance
2
------------
RKPV
Magnet Resistance in Parallel with Switch
2
--------------
RKPV
Mounting:
KROHVWDSSHGIRU0;RQWRSIODQJHHTXDOO\VSDFHG
RQDLQFKEROWFLUFOHGLDPHWHU
1.
Magnet not warranted for operation above 80 kG.
2.
All resistance measurements made at room temperature.
Example Magnet Specification Sheet
Summary of Contents for 430
Page 2: ......
Page 16: ...XVI REV 9 AMERICAN MAGNETICS INC FOREWORD SAFETY SUMMARY ...
Page 28: ...12 REV 9 AMERICAN MAGNETICS INC INTRODUCTION OPERATING CHARACTERISTICS ...
Page 64: ...48 REV 9 AMERICAN MAGNETICS INC INSTALLATION POWER UP AND TEST PROCEDURE ...
Page 208: ...192 REV 9 AMERICAN MAGNETICS INC SERVICE RETURN AUTHORIZATION ...
Page 248: ...232 REV 9 AMERICAN MAGNETICS INC APPENDIX SHORT SAMPLE MODE ...