19
2. Shake out the filter.
Rotate the manual shakeout handle approximately three
turns to the left, and then three turns to the right.
●
Automatic Shakeout Models (when using molded filter)
In most cases automatic shakeout provides adequate filter cleaning, so that no manual operation is required. But you can also
apply additional shakeout as necessary by holding down the SHAKING switch.
●
Automatic Shakeout
The cleaner automatically shakes out the filter for 10 sec-
onds, beginning 1 minute after you press the
OFF
switch.
The interval for carrying out filter shaking.
1
Once power is supplied, automatic filter shaking is per-
formed one minute after the cleaner is stopped for the
first time.
2
Subsequent automatic filter shaking is performed at the
following intervals.
In order to prevent the filter from wearing out, auto-
matic filter shaking will not be performed for 30 min-
utes after the last automatic filter shaking. If 30 minutes
has passed, automatic filter shaking is performed one
minute after the cleaner is stopped.
*
The cleaner will return to the condition described in
1
whenever you turn off the power supply of the cleaner.
●
Manual Shakeout
Apply additional shakeout by holding down the SHAKING
switch. Note that this switch does not operate unless the
blower motor has been switched OFF for at least 1 minute.