Checking
•
For wiring, use a shielded cable with a minimum thickness of 0.3 mm
2
and a minimum withstand voltage of AC 250 V.
•
The wiring for the remote-control switch must not be longer than 10 m.
•
The terminal block outputs signals at DC10V, 10mA.
•
Be sure to turn OFF the power supply before changing the DIP switch settings. Any changes made in the operation
patterns without turning OFF the power supply will be invalid.
•
The minimum application load specification of switches and relays used for remote control must be below DC10V,
10mA.
1. Turn OFF the power supply at the source.
To ensure safety, turn OFF the power supply at the source.
2. Open the electrical control door.
Remove the two screws that are securing the electrical con-
trol door in place, and open the electrical control door.
3. Connect the wires.
Route the signal wires through the hole (ø16) in the electrical
control door and extend it to the terminal block. Follow the
wiring diagram on the next page to connect the signal wires
to the terminal block. To protect the signal wires, install the
supplied grommet in the hole.
Electrical
control door
Install the grommet
■
Wiring and Setup Work
Signal
wires
Terminal
block