Replacing the Floor Brush
Wearing or deformation of the floor brush can cause the cleaner to lose suction force. If the brush becomes worn or bent,
replace it as follows.
1. Switch off the blower motor.
Press the
OFF
switch to shut down the blower motor. Wait
1 minute for the blower motor to stop.
2. Remove the brush
Remove the 8 screws holding the fastening plates in place.
The brush will come off when you remove the plates.
3. Install the new brush.
Set the new brush in place, then screw in the fastening plates
with the 8 screws.
■
Belt Inspection and Adjustment
If abnormal noise or vibration is produced near the belt or if there is a loss of suction strength during operation, check if the
belt is loose or broken.
1. Open the two access panels on the left and right
sides of the unit.
Caution:
Always unplug the power cable from the wall outlet before
beginning inspection or maintenance work.
Remove the screws holding the access panels in place of the
left and right sides of the unit, and then remove the access
panels.