Connecting the Power
This cleaner requires a 3-phase power supply. Before connecting up the power, make sure that your power supply matches the
power ratings given on the cleaner’s nameplate.
Warnings
• Be sure to use the rated voltage only. Do not place other loads on the same power
outlet.
Incorrect voltage or multiple loads may result in fire or electric shock.
• Never insert or remove the power cable while your hand is wet.
Doing so may result in electric shock.
• Do not allow the power cord to become damaged.
Do not let heavy objects rest on the cord, and do not pull it or excessively bend it. A damaged power cord may
result in fire or electric shock.
• Be sure to connect the ground.
If current leakage should occur due to failure to connect the ground, there is a risk of fire or electric shock.
There is also a risk that static electricity could cause damage to the equipment or faulty operation.
Cautions
• All wiring work must be performed by a competent electrician.
Failure to do so could cause accidents.
•
Plug the cord into a 3-phase AC power outlet.
•
Make sure that the ground is correctly connected.
•
Perform a test run and check whether the “Power Lamp” is ON or OFF. If it blinks red at 1-second intervals, it indicates that
the three-phase power supply is reversed. If this occurs, you must rearrange the wire attachments within the power-cable
plug so that the phase is correct.
•
Wait for more than 7 seconds after the primary power is supplied to the cleaner. During this time, the cleaner performs a self-
check (phase detection and power supply confirmation) and pressing the OPERATION
ON