Note
To operate the unit through remote control, perform the wiring and setup work described below.
■
Function
The operation patterns described below can be selected by changing the settings of the levers 1 and 2 of the DIP switch
(SW1), which is mounted on the control panel. The setting procedures are described in the next page.
(Do not change the settings of levers 3 and 4 unless you have been specifically instructed to do so. Their initial settings vary
by model.)
For Your Information
•
The wiring work for remote control must be performed by a licensed electrician.
External view of electrical control door
(Illustration: automatic shakeout type)
Selector switch
Internal view of electrical control door
Control panel
installation position
Control panel
Function
name
Pattern A
Pattern B
Pattern C
Pattern D
OFF
ON
OFF
ON
OFF
OFF
ON
ON
Selector switch
Lever
1
2
Yes
Yes
Yes
No/Yes
No
No
No
Description
Remote
Local
Remote
Local
Remote
Local
Enables the operation of the unit switch only. No remote
control.
Enables the operation of both the unit switch and the re-
mote-control switch.
Same as pattern A
Enables the operation of the remote-control switch only.
The unit switch is disabled.
Same as pattern A
The cleaner operates while the remote-control operation switch is ON. It
stops operating when the ON switch is disengaged. (The switch is the self-
holding type.) The operation switch on the unit is disabled. The shaking
switch is enabled both on the unit and on the remote-control switch.
Same as pattern A
·
The default factory setting is “ pattern B ”.
·
A shaking switch is provided on the automatic shakeout type, and not on the standard (manual shakeout) type.
·
“ Pattern D ” enables the cleaner to operate in unison with another machine.