In more than 250 ms after a beam select signal input or in more than the time set
on the MEMORY SWITCH screen after the setting of welding conditions, close
the LASER START pin.
⇒
At delivery, the laser start acceptance time (time from a signal input till an actual
output of laser light) is set to 16 ms. As the laser start acceptance time, 0.1 ms,
1.0 ms, 4.0 ms, 8.0 ms, or 16.0 ms can be selected by displaying the MEMORY
SWITCH screen from the INITIALIZE screen. For details, refer to Chapter 2, "3.
Changing the Acceptance Time for Laser Start Signal/Schedule Signal" on page
111.
⇒
Be sure to put the laser start pin in a closed circuit at least the time set on the
MEMORY SWITCH screen.
7
Setting Output Schedules (SCH.#02)
(1) Set the SCHEDULE number by combining pin No.29 to pin No.33 of the EXT.I/O
(1) connector. In this example, put pin No.29 of the EXT.I/O (1) connector to an
open circuit to turn OFF SCH.#01, and put pin No.30 in a closed circuit to turn on
SCH.#02.
⇒
Refer to "SCHEDULE Number Selection" on page 131.
8
Outputting Laser Light
(1) Put pin No.20 (Laser start) of the EXT.I/O (1) connector in a closed circuit.
Laser light is output simultaneously from BEAM1 and BEAM2.
⇒
The details are the same as Step
6
.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(Laser light)
End output
Control switching
input
Ready output
SCHEDULE 1
input
SCHEDULE 2
input
BEAM SELECT 1
input
BEAM SELECT 2
input
Laser start input
HV-ON
OFF
input
External input
acceptable input
Laser output
End output
SCHEDULE 1
input
SCHEDULE 2
input
Laser start input
Monitor normal/
trouble output
Monitor normal/
trouble output
The time set on the MEMORY SWITCH
screen
50
ms
0.02
ms or more
16.0
ms or more
Output
40
ms
Output
16.0
ms or more
31 sec. max.
16.0ms or more
250
ms or more
Completion of charging
Over the time set on the MEMORY
SWITCH screen
↓ ↓ ↓
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Laser output
End output
Control switching
input
Ready output
SCHEDULE 1
input
SCHEDULE 2
input
BEAM SELECT 1
input
BEAM SELECT 2
input
Laser start input
HV-ON
OFF
input
External input
acceptable input
Laser output
End output
SCHEDULE 1
input
SCHEDULE 2
input
Laser start input
Monitor normal/
abnormal output
Monitor normal/
abnormal output
Over the time set
on the MEMORY
SWITCH screen
50
ms
16.0
ms or more
Output
50
ms
Output
31 sec. max.
16.0ms or more
16.0ms or more
40
ms or more
150
ms or more
Completion of charging
↓
Summary of Contents for ML-2550A
Page 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 116: ......
Page 144: ......
Page 168: ......
Page 173: ...Maintenance Part...
Page 174: ......
Page 203: ...Appendixes...
Page 204: ......