122
ML-2550A/2551A
3. Operating Procedure
<Note>
The settable maximum peak value of laser output differs depending on the model.
For the laser output value setting (% of FLASH), set a value not exceeding the
maximum value of each model.
ML-2550A: 8.0 kW
ML-2551A: 5.0 kW
(4) Press the "TIME [ms]" setting button of "FLASH1."
Enter the laser output time (ms) by using the numeric keypad and then press the
ENT key.
In this example, set 03.6 ms in "FLASH1."
<Note>
Set the laser output time so as to result in the following value.
0.25 ms ≤ "FLASH1" + "FLASH2" + "FLASH3" ≤ 100.0 ms
(5) Press the "
SLOPE" setting button.
Enter the time "TIME [ms]" required for laser light to up-slope (get gradually
stronger) in FLASH1 by using the numeric keypad, and then press the ENT key.
In this example, set 00.6 ms.
<Note>
Set "
SLOPE" so as to result in the following value.
SLOPE ≤ FLASH1
When setting "FLASH2" or "FLASH3", set the time required for laser light to down-
slope (the laser output is gradually weaker) to FLASH. Set "
SLOPE" so as to
result in the following value.
SLOPE ≤ FLASH1, FLASH2, FLASH3
(6) Press the "POWER [%]" setting button of "FLASH1."
Enter the laser output value (%) by using the numeric keypad and then press the
ENT key.
In this example, set 060.0% in "FLASH1."
Summary of Contents for ML-2550A
Page 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 116: ......
Page 144: ......
Page 168: ......
Page 173: ...Maintenance Part...
Page 174: ......
Page 203: ...Appendixes...
Page 204: ......