52
ML-2550A/2551A
4. Connecting the Optical Fiber
(4) Put the end of the optical fiber into the optical fiber inlet with the cap mounted.
(5) Remove the cap from the end of the passed fiber and blow off any dust using an
air blow.
(6) Connect the fiber to the laser beam input unit, with the key of the fiber plug
aligned with the groove of the unit.
(7) Turn the outer-side ring of the plug in the direction of the arrow to fix the optical
fiber.
⇒
Tighten the ring by hand without using a tool.
(8) Install the branch unit cover and top cover as they were.
(9) Return the control panel to the initial position and fix it.
Key
Groove
Laser Beam Input Unit
Cap
Ring
Turn
Plug
Turn the outer ring of the
plug in the direction of arrow
to fix.
There are 2 optical fiber inlets, namely, one on the top surface and
the other on rear surface of the main unit.
To output unit
To input unit
Optical fiber
Optical fiber inlet
Rear surface