1. Setting Welding Schedules
97
ML-2550A/2551A
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
The items that can be protected are as follows.
Display Screen
Item
SCHEDULE Screen
SCHEDULE (Schedule number)
FORM (FIX/FLEX waveform switching)
PEAK POWER (Laser output peak value)
SEAM (Fade function ON/OFF)
REPEAT (Number of laser light outputs per second)
SHOT (Total number of laser light outputs)
SLOPE (Time for up-sloping to FLASH1)
FLASH1 (Output time ms and output value % of the first laser)
COOL1 (Non-laser output time to be inserted between FLASH1 and FLASH2)
FLASH2 (Output time ms and output value % of the second laser)
COOL2 (Non-laser output time to be inserted between FLASH2 and FLASH3)
FLASH3 (Output time ms and output value % of the third laser)
SLOPE (Time for down-sloping to the last FLASH)
POINT 01 to 20 (Output time ms and output value % of each point for FLEX)
SEAM Screen
SCHEDULE (Schedule number)
FORM (FIX/FLEX waveform switching)
SHOT (laser light output count of each No. of POINT 01 to POINT 20)
POWER (laser output value % of each No. of POINT 01 to POINT 20)
STATUS Screen
SCHEDULE (Schedule number)
FORM (FIX/FLEX waveform switching)
POSITION BLINK (Guide light blinking or lighting ON/OFF)
FIBER
TYPE (SI/GI)
SIZE (Setting core diameter)
RESET COUNT
SHOT COUNT (Resetting the total number of laser light outputs, SHOT COUNT)
GOOD COUNT (Resetting the appropriate number of laser light outputs, GOOD
COUNT)
PRESET COUNT
SHOT COUNT (Conut-notification setting of the total number of laser light
outputs, SHOT COUNT)
GOOD COUNT (Conut-notification setting of the appropriate number of
laser light outputs, GOOD COUNT)
MONITOR Screen
SCHEDULE (Schedule number)
FORM (FIX/FLEX waveform switching)
HIGH (Upper limit value of laser energy to be monitored)
LOW (Lower limit value of laser energy to be monitored)
REFERENCE SETTING (Upper limit value of lamp input power)
The above setting items become unchangeable and the set values are protected.
⇒
To change any set value, enter the password to display the password setting
screen and turn ON "VALUE CHANGE."
Summary of Contents for ML-2550A
Page 1: ...AA06M0642E 37 OPERATION MANUAL YAG LASER WELDER ML 2550A 2551A...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 116: ......
Page 144: ......
Page 168: ......
Page 173: ...Maintenance Part...
Page 174: ......
Page 203: ...Appendixes...
Page 204: ......