ML-2550A/2551A
3. Operating Procedure
<Note>
To stop the laser light by closing the branch shutter, the output per delivery
should be 50 J/P or less. And observe the time that allows the branch shutter to
continuously receive laser light, by referring to the following graph. For example,
in the case of an output of 270 W per delivery, the time that allows the branch
shutter to continuously receive laser light is 5 seconds.
The average power (average value displayed on the MONITOR screen) should be
100 W or less per delivery. After the 300 W output is stopped for 2 seconds, the
branch shutter should not receive any laser light for 18 seconds.
0
5
10
15
20
25
30
0
100
200
300
400
Laser output per delivery (W)
Time that allows the branch shutter to
continuously receive laser light (sec)