CHAPTER 4: OPERATING INSTRUCTIONS
STA SERIES AC CONTROLS
990-351
4-13
CHANGED FROM RUN MODE TO PROGRAM MODE
IN THE MIDDLE OF A WELD, OR TURNED
OFF WELD CURRENT DURING A WELD. WELD
WAS ABORTED.
PRESS RESET BUTTON, THEN RESTART THE
WELD FROM THE BEGINNING.
Minor Run-Time Error Messages
SCHEDULE 01
WELD 1 CURRENT BELOW LOW LIMIT.
1. REPROGRAM WELD 1 CURRENT.
2. DECREASE WELD TRANSFORMER RATIO.
3. DECREASE W1 LOW LIMIT AT THE
MONITOR
SCREEN.
PRESS RESET BUTTON TO RESUME WELDING
SCHEDULE 01
WELD 2 CURRENT BELOW LOW LIMIT.
1. REPROGRAM WELD 2 CURRENT.
2. DECREASE WELD TRANSFORMER RATIO.
3. DECREASE W2 LOW LIMIT AT THE
MONITOR SCREEN.
PRESS RESET BUTTON TO RESUME WELDING.
SCHEDULE 01
REACHED THE LAST STEP COUNT FOR
CURRENT STEP. THE NEXT WELD WILL
MODIFY WELDING CURRENT USING THE
PERCENTAGE FACTOR SPECIFIED IN THE NEXT STEP
OF THE CURRENT STEPPER
SCHEDULE.
PRESS RESET BUTTON TO RESUME WELDING.
WELD COUNT REACHED WELD COUNT LIMIT.
IMPLEMENT USER DEFINED PROCEDURE FOR
THIS CONDITION.
AT THE MONITOR SCREEN:
1.
SET WELD COUNT=0 OR
2.
INCREASE WELD COUNT LIMIT.
Summary of Contents for Miyachi Unitek STA-100A
Page 1: ...990 351 Rev H AC WELDER STA SERIES OPERATION MANUAL...
Page 24: ......
Page 28: ......
Page 48: ......
Page 64: ......
Page 68: ...CHAPTER 5 MAINTENANCE STA SERIES AC CONTROLS 5 4 990 351...
Page 78: ......
Page 90: ......
Page 96: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 2 990 351 Continuous Seam Weld...
Page 98: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 4 990 351 Spot Welding...
Page 102: ......
Page 104: ......
Page 108: ......
Page 112: ......
Page 140: ......
Page 144: ......