APPENDIX J: COMMUNICATION OPTION
STA SERIES AC CONTROLS
990-351
J-5
Host Originated Command Set
These are commands sent by the host computer, via the RS-485/RS-232 port to the STA.
NAME COMMAND
DATA
SIZE
TYPE
“TY” Read
none
0 Bytes
REPORT “RR”
Read Retransmission = 0x0FF
1 Byte
RESET
“RX” Set
Reset an Error and Returns
STATUS
0 Bytes
REMOTE “RM” Set
0=Local, 1=Remote
1 Byte
LOAD
“LR” Read
none
0 Bytes
“LS” Set
The schedule # to become active
1 Byte
COUNTER “CS” Set
Schedule # to Reset the Counter
1 Byte
COPY
“CP” Set
Source schedule #
1 Byte
Destination schedule #
1 Byte
Count past
1 Byte
3
Bytes
Total
TIME CLK “RT” Set
<data>=0 Reset Time Clock
1 Byte
“RT” Read
<data>=1 Read Time Offset
1 Byte
LINK
“KR” Read
none
0 Bytes
“KS” Set
SCHEDULE #, SCHEDULE #,…
64 Bytes