1
Use the
buttons on the
Control panel to highlight the valve
number for the channel to be calibrated.
Press
PROGRAM/SAVE
to put the unit
into program mode. Input the valve
number that supplies air to the head to
be calibrated.
000 *** FORCE CALIBRATION ***
Psi (All Force Entries in Pounds)
Channel-----------------Valve Channel-----------------Valve
# Lo-Psi Hi-Psi # # Lo-Psi Hi-Psi #
F1 0000 0001 1 F5 0000 0001 N/A
F2 0000 0001 2 F6 0000 0001 N/A
F3 0000 0001 N/A F7 0000 0001 N/A
F4 0000 0001 N/A F8 0000 0001 N/A
2
Move the cursor to “Lo-Psi.”
3
Place a force gauge between the
electrodes.
4
Press the
WELD ON
button on the
Control Panel to close the electrodes.
NOTE:
In
FORCE CALIBRATION
mode, the Control will
not
send weld
current to the electrodes.
5
Let the force stabilize, then check the
force on the force gauge. Press the
WELD ON
button to release the
weldhead. Enter the number of pounds
under
Lo-Psi
on the LCD screen.
6
Select “Hi-Psi” on the control.
7
Place a force gauge between the electrodes.
8
Press the
WELD ON
button on the Control Panel to close the electrodes.
9
Let the force stabilize, then check the
force on the force gauge. Press the
WELD ON
button to release the
weldhead. Enter the number of pounds
under
Hi-Psi
on the LCD screen. Press
the Program/Save button to save this
information. Calibration for this
000 *** FORCE CALIBRATION ***
Psi (All Force Entries in Pounds)
Channel Valve Channel-----------------Valve
# Lo-Psi Hi-Psi # # Lo-Psi Hi-Psi #
F1 0119 0364 1 F5 0000 0001 N/A
F2 0000 0001 2 F6 0000 0001 N/A
F3 0000 0001 N/A F7 0000 0001 N/A
F4 0000 0001 N/A F8 0000 0001 N/A
Channel is now complete.
Example:
As shown on the right, Low Pressure was
119 lbs
, High Pressure was
364 lbs.
10
Repeat Steps 3-10 to calibrate other channels.
Summary of Contents for Miyachi Unitek STA-100A
Page 1: ...990 351 Rev H AC WELDER STA SERIES OPERATION MANUAL...
Page 24: ......
Page 28: ......
Page 48: ......
Page 64: ......
Page 68: ...CHAPTER 5 MAINTENANCE STA SERIES AC CONTROLS 5 4 990 351...
Page 78: ......
Page 90: ......
Page 96: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 2 990 351 Continuous Seam Weld...
Page 98: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 4 990 351 Spot Welding...
Page 102: ......
Page 104: ......
Page 108: ......
Page 112: ......
Page 140: ......
Page 144: ......